JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
251
Graphic programming command reference
9.7.10
Unconditional jump
9.7.11
Conditional jump (single input)
Icon:
Dialogue: None. After selecting this command, the mouse cursor changes. The next
program line that you click on will become the destination for the jump.
Function: Jumps to another line in the program.
Icon:
Dialogue:
Function:
Tests for an input condition before either jumping to another line in the
program or moving on to the next line in the program. If the condition is met,
the command jumps to the specified program line. If the condition is not met,
the program proceeds to execute the next line in the program.
When ‘Input type’ is set to ‘Single’, the command can test a single input for one
of four possible conditions: the input is low, the input is high, the input has
transitioned to low (Falling Edge), or the input has transitioned to high (Rising
Edge). If transitions are tested for, the transition must have taken place during
the last 30 microseconds.
After pressing the OK button, the dialogue will disappear, and the mouse
cursor will change. The next program line that you click on will then become
the destination of the jump command.
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...