33
Item
Setting value
Functions and settings
TIME
●
5s
6s
7s
8s
9s
10s
15s
20s
30s
60s
This item sets the alarm signal output time and alarm title display time that are
output when there is an alarm.
Memo
:
●
When [ALARM INPUT] item is
A
OFF
B
Page 35), and
A
ALARM IN1 to 6
B
is set,
A
- - -
B
will be displayed and settings is disabled.
Note
:
●
This setting is invalid in a RM-P2580 system. Set in the [ALARM TIME] item
of RM-P2580. (
A
RM-P2580 Instruction Manual)
PRIORITY
●
ALARM
MANUAL
This item sets the operation for alarm input when the camera is operated
manually.
ALARM
:Alarm activates when there is an alarm input regardless of whether
the camera is in manual operation or not. (Alarm operation has
priority)
MANUAL :Alarm does not activate even if there is an alarm input during manual
operation. (Manual operation has priority)
Memo
:
●
When [ALARM INPUT] item is set to
A
OFF
B
,
A
- - -
B
will be displayed and
settings is disabled.
●
This setting is invalid in a RM-P2580 system.
A
ALARM
B
mode will take over.
ALARM OUTPUT..
This item sets the alarm output terminal.
OUTPUT1
OUTPUT2
●
OFF
ALARM
B&W
PRESET
AUX1
AUX2
AUX3
OFF
:Alarm does not output.
ALARM
:When there is an alarm input, alarm signals will be output and will
continue during alarm display.
Memo
:
●
Alarm signals will also be output when there is an alarm input in the system
control unit or RM-P2580.
B&W
:When this unit is in B&W mode, alarm signals will be output and will
continue throughout the B&W mode.
PRESET :Alarm signals are output when the camera is moved to the home
position or to a preset position.
AUX1,AUX2,AUX3
:Alarm signals are output when there is an auxiliary input.
Memo
:
●
In normal cases, do not use
A
AUX1
B
,
A
AUX2
B
,
A
AUX3
B
. For details, please
consult your nearest JVC dealer.
TK-C686E_EN.book Page 33 Tuesday, December 4, 2007 4:45 PM