E-33
Item
Functions and set values
Initial value
FACTORY
SETTINGS
Set values are returned to initial values.
The values set on the menu are returned to initial values.
CANCEL
: No return to the initial value.
CLEAR
: Returns set values except titles to the
(WITHOUT TITLE)
initial value.
CLEAR (ALL)
: Returns all set values including titles
to the initial value.
Select respective set value and press the SET button.
Then, “DATA CLEARED” will appear for about 3 seconds.
Be sure not to switch off the power while the display is
still on.
MEMO
However, when making settings by means of transmitted
commands, the contents of the COMMUNICATION menu
do not return to the factory settings.
–
This sets a communication system according to the
system used.
P TO P (Point to point)
This is set when a remote control unit controls a camera.
M.DROP (Multi-drop)
This is set when a remote control unit controls a plural
number of cameras.
This is set when the STYLE item is set to M.DROP. This
is the number that identifies individual cameras in a group.
No proper function can be realized if an ID number is
repeated within a system.
A combined use with the RM-P2580 necessitates the
setting together with the video input number of the RM-
P2580.
If the item STYLE is set to P TO P, “- - -” will appear, and
settings cannot be changed.
[Set values: 1 to 99]
COMMUNICATION Screen
Item
Functions and set values
Initial value
STYLE
MACHINE ID
Settings are made for the control signal-connecting terminals on the back.
If the setting is changed, be absolutely sure to switch on the power again.
P TO P
– – –
FACTORY SETTINGS Screen