(No.MA403<Rev.001>)1-27
SECTION 4
ADJUSTMENT
4.1
Test instruments required for adjustment
(1) Digital oscilloscope (100MHz)
(2) Electric voltmeter
(3) Digital tester
(4) Tracking offset meter
(5) Test Disc : VT501 or VT502
(6) Extension cable : EXTCN001-6P (CN851 - CN961) X1
EXTFP001-30P(CN802-WR981)x1
EXTFP001-12P(CN606-CN801)x1
EXTXD002-60PF(CN606-CN401)x1
(CN503-CN881)x1
EXTDV001-30P(CN981-CN605)x1
EXTLX001-4P(CN982-CN607)x1
(7) Extension studs : STDV001-3P
4.2
Standard measuring conditions
Power supply voltage DC14.4V(10.5 to 16V)
Load impedance 20K.(2 Speakers connection)
Output Level Line out 2.5V (Vol. MAX)
4.3
Standard volume position
Balance and Bass &Treble volume : lndication"0"
Loudness : OFF
4.4
Dummy load
Exclusive dummy load should be used for AM,and FM.
For FM dummy load, there is a loss of 6dB between SSG output
and antenna input.
The loss of 6dB need not be considered sincedirect reading of
figures are applied in this working standard.
4.5
How to connect the extension cable for adjusting
Caution:
Be sure to attach the heat sink and rear bracket onto the power amplifier IC and regulator IC respectively,
before supply the power.
If voltage is applied without attaching these parts, the power amplifier IC and regulator IC will be destroyed by heat.
Extension studs
STDV001-3P
CN401
CN401
CN401
Extension cable
EXTCN001-6P
CN961
CN851
CN605
CN607
CN607
CN607
CN602
EXTFP001-30P
EXTFP001-30P
EXTFP001-30P
EXTFP001-30P
CN606
EXTXD002-60PF
EXTDV001-30P
EXTLX001-4P
CN982
CN982
CN982
WR981
WR981
WR981
EXTXD002-60PF
1
2
CN881
CN503
CN503
CN503
EXTFP001-12P
EXTFP001-12P
EXTFP001-12P
CN801
CN801
CN801
insid
e and outs
id
e
CN802
CN802
CN802
EXTXD002-60PF
EXTXD002-60PF
EXTXD002-60PF
CN981
CN981
CN981