Setting Time Code
Generator
Presetting the Time Code
Time code and user’s bit data generated from the
internal time code generator are recorded.
This section describes how to set [TC/UB]
B
[TC
Preset].
Memo :
0
When [Main Menu]
B
[System]
B
[Record Set]
B
[Record Format]
B
[
W
Frame Rate] is set to
“50p”, “50i” or “24p”, setting for “Drop” will be
disabled.
0
You can configure the setting without accessing
the [TC/UB] menu screen.
P71 [Setting Time Code without Opening
Required Settings Before Preset
1
Set [TC/UB]
B
[TC Generator] to “Rec
Run” or “Free Run”.
0
[Rec Run]:
Preset data in the time code generator
operates in run mode during recording mode.
Set this when recording continuous time
code in connecting frames.
0
[Free Run]:
Time code starts to operate in run mode from
the preset time in the time code generator.
2
Select the framing mode for the time code
generator (only when the frame rate setting
is “60” or “30”).
Set using [Main Menu]
B
[TC/UB]
B
[Drop
Frame].
0
[Drop]:
Sets the run mode of the time code generator
to drop frame mode. Use this setting when
placing emphasis on the recording time.
0
[Non Drop]:
Sets the run mode of the time code generator
to non-drop frame mode. Use this setting
when placing emphasis on the number of
frames.
Memo :
Drop frame/non-drop frame mode
0
When [Main Menu]
B
[System]
B
[Record Set]
B
[Record Format]
B
[Frame Rate] is set to
“60p”, “60i”, or “30p”, the actual number of
frames per second is approximately 59.94
(29.97). However, the time code processing
standard is “60p”, “60i”, or “30p” frames. To
make up for the frame number discrepancy, the
drop frame mode (Drop) drops the 00 frame and
01 frame every minute except for minutes that
are multiples of 10. However, in the case of
“60p”, the 00, 01, 02 and 03 frame are dropped.
0
The non-drop frame mode (Non Drop) does not
drop frames and ignores the discrepancy with
the actual time.