(No.PA023)1-7
SECTION 2
SPECIFIC SERVICE INSTRUCTIONS
2.1
NEW TECHNOLOGY
2.1.1 New optical engine with wire-grid polarizers
Using a conventional PBS (Polarizing Beam Splitter), comprised of a glass prism on which has been deposited a multilayer interfer-
ence film, optical properties can vary considerably depending on the angle of the incident light beam; this makes it difficult to realise
high contrast.However, the wire grid design employed for JVC's newly developed optical engine uses an inorganic reflective polarizing
plate made from a glass substrate on the surface of which are aluminium ribs with a width of a 20~30 nanometers, aligned with a pitch
of 120~130 nanometers. This has very little angle-dependence and it succeeds in reducing to an absolute minimum the amount of
stray light reaching the lens during dark scenes. The combination of this polarizer with the newly developed D-ILA device increases
contrast by a factor of 5
2.1.2 Image processing circuit with video processor made by Gennum Corporation
images thanks to a high-precision scaling function and four VXP
™
technologies as the followings.
VXP
™
Technologies
FineEdge
™
Edge correction technology that gets rid of the jaggy artifacts
that can affect diagonal lines, creating instead smooth out-
lines.
FidelityEngine
™
Imaging technology that improves detail while reducing noise.
This technology ensures a clear, detailed picture even when
using video sources with lower resolutions.
TruMotionHD
™
De-interlacing technology that supports HD signals (1080i),
converting them to high-quality 1080p signals for playback.
RealityExpansion
™
10-bit image processing technology. This technology can up-
sample 4:2:2 (Y:Cb:Cr) video signals to the 4:4:4 format; it de-
livers outstanding image processing at a level comparable to
that of broadcast masters.
2.2
MAIN DIFFERENCE LIST
2.3
FUNCTIONS
2.3.1 LED indications
The LED operations are as follows.
STAND-BY LED
LAMP LED
WARNING LED
CAUTION:
Please refer to the Trouble Shooting section for the details of warning indications by LED
Part Name
DLA-HD1-BC
DLA-HD1-BE
DLA-HD1-BU
POWER CORD
QMPS210-200-JC
QMPL040-200-JC(EU)
QMPP170-200-JC(EK)
QMPE330-244-JC
LAMP UNIT
BHL5009-SC
BHL5009-S
←
Light on (Red)
: Standby mode
Light on (Green)
: During projection
Blinking (Green)
: Image is temporarily hidden
Blinking (Red)
: Cool Down mode
Blinking (Red/Green)
: Adjust mode
Light on
: Light on:Lamp replacement is near.(The LED lights when the lamp is used more than 1900 hours)
The [Lamp replacement] message appears on the screen when the unit is turned on.
Lamp cover is not put on.
No projection due to a non-lighting lamp.
Lamp becomes extinction during the projection.
Blinking
: Lamp does not light up and unit is unable to project.Lamp is turned off during projection.Lamp cover is removed
Extinguished : Other than the above. (The lamp is normal)
Lighted
: Internal fan not operated.
Extinguished : Lamp life terminated, lamp under replacement, or Main unit malfunctioned