E-12
Installation and connection
Mounting the Camera to the Ceiling (Continued)
9.
10.
11.
Connection for Adjustment of the Camera
* The power to the camera body must be ON when adjustments are performed.
FOR
SERVICE
MONITOR
FOCUS ADJ.
OFF
OFF
OFF
ON
ON-AGC
ON-BLC
INT
WHT.BAL.
LL
PHASE
AUTO
MANU
R
B
RESET
SPOT
CORRECTION
IRIS
L
H
LEVEL
Temporarily used for making various adjustments
while the camera remains in the installed location.
CAUTION:
• Do not hold the lens part when mounting
the unit to the ceiling or wall.
• When directly mounting the unit to the
ceiling or wall, fix the unit using all 4
mounting holes.
• Use M4 screws or bolts for attaching the
ceiling mount.
• If wood screws are used, use screws
with a diameter of 4.1 mm.
4 inch square
electrical box
Mounting
holes
Shooting
direction
Screws
M o u n t -
ing
holes
IRIS
LEVEL Volume
75
Ω
termination
disconnected
Adjustment
button
Setting switch
Monitor TV
BNC connector
Power supply
cable
Roll with tape
9.
Roll cables with insulation tape.
As shown in the diagram to the left, roll
the entire connecting section of the
power supply cable and BNC connec-
tor with insulation tape and insert them
in the electrical box.
MEMO
Rolling cables with insulation tape not only
increases the work efficiency later on, but
reduces the entry of noise, etc.
10
.
Adjust the unit in the direction to shoot.
11
.
When using an electrical box, use the
2 mounting holes to fix the box to the
unit.
E-13
English
FOR
SERVICE
MONITOR
FOCUS ADJ.
OFF
OFF
OFF
ON
ON-AGC
ON-BLC
INT
WHT.BAL.
LL
PHASE
AUTO
MANU
R
B
RESET
SPOT
CORRECTION
IRIS
L
H
LEVEL
50˚
80˚
Adjusting the Camera Angle
Horizontal rotation
(adjustable range: 120°)
1.
Loosen the horizontal LOCK screw.
2.
Holding the both tilt lock screws, rotate
horizontally.
3.
Tighten the horizontal LOCK screw.
Vertical rotation
(adjustable range: +80°, -50°)
1.
Loosen the tilt lock screws.
2.
Holding the rotation levers, rotate
vertically.
3.
Tighten the tilt lock screws.
Image inclination
(adjustable range: ±15°)
Manipulate the rotation levers to adjust the
inclination of the image.
Adjusting the image size
Adjust the size using the zoom ring.
Adjusting the focus
Adjust using the focus ring.
When adjusting the focus, set the FOCUS
ADJ. switch to “ON”. After adjustment is
completed, set the FOCUS ADJ. switch to
“OFF”.
When required, the surveillance image
should be adjusted, etc.
Horizontal
Lock screw
Tilt lock
screws
Variable
range 120˚
Vertical rotation
Rotation levers
Zoom ring
Focus ring
Tilt lock screws
Summary of Contents for C205U - Network Camera
Page 10: ...Focus chart ...