Programmable Options Table
Option Function
Default
Description
01
Voltage alarm level
zone 1
20V
Sets the voltage below which
the fence alarm will occur. If
the return voltage falls below
this level for more than the
Missed pulse count a fence
alarm (zone 1) will occur.
02
Not Used
0
03
Not Used
0
04
Not used
0
05
HV sensitivity
75
0-99%. Setting 0 turns HV
alarms off (yet to be
implemented)
06
Missed Pulse Count 3
Sets the number of pulses
which may be missed before
the alarm is activated
07
Battery Alarm Volt
-
age
2 (10V)
Sets the battery voltage
threshold below which the
general alarm will activate
08
Not Used
0
09
Not Used
0
10
Not Used
0
11
Input type
0 (N/O) Allows the control input (IN1)
to be changed from normally
open to normally closed.
12
Not Used
0
13
Not Used
0
14
Chime Mode
2 (siren) Allows the keypad and internal
beeper function to be altered
15
Not Used
0
16
Binary Options
0
Not Used
17
Not Used
0