background image

Assembly and instruction manual 

DLS Color Viewing Light V7 L 

Art. Nr.: 202686 / 202443*

DLS COLOR VIEWING LIGHT V7 L

*Data for US version of the product

GER

 

|

  JUST Normlicht GmbH  |  Ve Produktion  |  Tobelwasenweg 24  |  73235 Weilheim / Teck  |  Tel.: +49 (0) 7023 9504-0  |  Fax: +49 (0) 7023 9504-52 

US

 

JUST Normlicht Inc.  |  2000 Cabot Blvd. West, Suite 120  |  Langhorne, PA 19047-2408  |  Phone: +1 267 852 2200  |  Fax: +1 267 852 2207  

FR

 

|

  JUST Normlicht France SARL  |  3 Rue Louis Pasteur  |  67240 Bischwiller  |  Tel.: +33 (0)3880628-22  |  Fax: +33 (0)3880628-23

Summary of Contents for 202443

Page 1: ...GER JUST Normlicht GmbH Vertrieb Produktion Tobelwasenweg 24 73235 Weilheim Teck Tel 49 0 7023 9504 0 Fax 49 0 7023 9504 52 US JUST Normlicht Inc 2000 Cabot Blvd West Suite 120 Langhorne PA 19047 2408 Phone 1 267 852 2200 Fax 1 267 852 2207 FR JUST Normlicht France SARL 3 Rue Louis Pasteur 67240 Bischwiller Tel 33 0 3880628 22 Fax 33 0 3880628 23 ...

Page 2: ...tion 3 Intended use 4 Safety precautions 5 Product description 8 Packing list and accessories 9 Mounting instruction 10 Operating instruction 11 Technical and electrical specifications 12 Troubleshooting 13 Maintenance information 14 Warranty policy 15 Return Material Authorisation RMA 16 Contact details 18 Document history 19 ...

Page 3: ...age 05 These instructions explain the device you have purchased and its features This will ensure your safety as well as reliable operation and a long service life The technical data illustrations and dimensions in this manual may vary due to future product enhancement Please check online for the most current product documentation If you have any questions or suggestions please do not hesitate to ...

Page 4: ...d and fluorescent materials and surfaces according to valid norms and standards The DLS Color Viewing Light V7 booths may only be operated in an indoor environment protected from humidity dust and condensation Never use DLS Color Viewing Light V7 products in poorly ventilated locations where there is a risk of explosion from gas or dust Please note that JUST Normlicht light sources are not intende...

Page 5: ...rmal part of our quality control process and is not due to prior use or a returned product This does not affect the product use or function and does not constitute a reason for return Keep these operating instructions for later use or inquiries If you pass the lamp on to a third party please include the operating instructions These operating instructions can be requested from the dealer as a PDF f...

Page 6: ...nded electrical outlets Repair and tube replacement Do not make any repairs or modifications to your proofing device or the power cable Defective luminaires may only be replaced by the manufacturer because incorrect repairs can cause considerable consequential damage In case of defects contact the responsible sales department see page 18 Care instructions Care must be taken to ensure that no moist...

Page 7: ...ution UVA Radiation Do not look directly into the source Avoid shining the light on uncovered skin less than 1 meter away for long periods of time Other notes Protect your device from moisture when in use Do not use multiple sockets Avoid pulling on the power supply to disconnect the device from the power supply Only use accessories supplied with or suitable for your device by the manufacturer Do ...

Page 8: ...rther advantages in color assessment and quality control through the innovative DLS solution The innovative and cost effective LED based light booth includes high uniformity and optimal spectral characteristics shadow and glare free CAD based prismatic diffusing lens for unprecedented stan dard compliant brightness and uniformity of light distribution expected life of 50 000 hours 3 illuminants ac...

Page 9: ...essories for your viewing booth that are supplied with the device or provided by the manufacturer Use of inadequate equipment can create significant hazards For example prevent tipping with suitable wall mounts bases or cabinets and damage to the coated viewing surface with unsuitable sample holders or rigid stands Do not attach any objects to the product that are not included with the system This...

Page 10: ...ht v7 L Rev 1 0 Mounting instruction Step 1 Mount the rear wall to the base using 3 x AM4 screws Step 2 Mount the sidewalls to the base using 4 x AM4 screws Step 3 Mount the DLS lamp on the assembled base using 4 x AM4 screws Step 4 Monut the cover on the assembled housing with 3 x M5 Screw ...

Page 11: ...n B which only refers to the D65 C and D50 A light types 5 Turn off the luminaire by pressing the light type A C or D 6 The unit can be switched off via the black main switch Notes When the luminaire is switched on again the last set values are used memory Regardless of the memory function the set dimming value and light type with and without UV component can be saved by holding down P1 or P2 butt...

Page 12: ...xpected lifetime continuous operation 50 000 h Photometric data and colormetric characteristics Illuminant types CIE D50 5000 K CIE D65 6500 K UV ONLY UV A Ra Color Rendering Index ø 95 Metamerism Index visible range 0 8 Metamerism Index UV range 0 6 Chromaticity error 0 002 Chromaticity coordinate 10 D50 x 0 3478 y 0 3595 D65 x 0 3138 y 0 3309 Dominant wavelength UV ONLY 365 nm Radiant power UV O...

Page 13: ...them on if necessary The light does not turn on There is no power or the fuse for the light has blown First check whether you ve got power and whether the device is connected to the right power supply in accordance with its specifications 110 V or 230 V Check the lamp s fuse or have it checked by an electrician You can usually find it at the device s main input If you have any issues please contac...

Page 14: ...t v7 L Rev 1 0 Maintenance information The manufacturer recommends that the booth be maintained in case of possible deviating color temperatures D50 D65 after 50 000 operating hours to ensure uniformity and consistent light quality For maintenance please contact your local dealer see page 18 ...

Page 15: ...s not manufactured distributed or approved by JUST Normlicht 5 Any attachments or modifications to the warranted goods that are not manufactured distributed or approved by JUST Normlicht 6 Failure to use electrical protection Consumable parts and product cleaning are also not covered by the warranty Warranty is extended to the purchasing party only and not transferable to a second party if re sold...

Page 16: ...chaser shall obtain a Return Material Authorization RMA number from JUST Customer Service Department and mark the outside of all packages with the RMA number Products must be new unused and contain all the original packaging instruction manuals and accessories There is no restocking charge due to errors by JUST if correct order information was furnished with the order Custom order returns The retu...

Page 17: ...er are responsible for any shipping damages Shipping damages resulting from improper packaging will be at the customer s responsibility After repair JUST will return the product ground freight prepaid for in warranty items For any other shipment method customer must pay the difference in freight Non Warranty items will be invoiced for any parts labor and shipping charges Products will not be accep...

Page 18: ...ermany International phone 49 7023 9504 0 E Mail info just normlicht com Sales Team USA Canada Mexico phone 1 267 852 2203 E Mail sales just normlicht com Sales Team France Benelux Spain Portugal Morocco Algeria Libya Tunisia phone 33 3 8806 2822 E Mail info just normlicht fr For more infortamion about our company and products visit our website www just normlicht com our social media channels ...

Page 19: ... 19 Errors and changes are reserved Assembly and instruction manual DLS Color Viewing Light v7 L Rev 1 0 Document History Rev Nr Modification date Modification Internal ID ...

Page 20: ......

Reviews: