Jupiter Avionics JA74-410 Installation And Operating Manual Download Page 1

 

 

Rev A 

 

Page i 

 

JA74-005 

Glove Box with USB-A and USB-C Charger - 1  

 

  

 

 

JA74-410 USB-A and USB-C Charger 

 

 
 
 
 
 
 

Installation and Operating Manual 

 

Rev. A    

Jupiter Avionics Corporation 

1959 Kirschner Road 

Kelowna BC 

Canada   V1Y 4N7    

Tel: +1 778 478 2232 

Toll-Free: 1 855 478 2232 

www.jupiteravionics.com 

 

 

 

Summary of Contents for JA74-410

Page 1: ...SB A and USB C Charger 1 JA74 410 USB A and USB C Charger Installation and Operating Manual Rev A Jupiter Avionics Corporation 1959 Kirschner Road Kelowna BC Canada V1Y 4N7 Tel 1 778 478 2232 Toll Free 1 855 478 2232 www jupiteravionics com ...

Page 2: ...distribution of this manual is strictly prohibited Except as described above no part of this manual may be reproduced copied transmitted disseminated downloaded or stored in any storage medium for any purpose without the express prior written consent of JAC RECORD OF REVISIONS Revision Rev Date Description ECR A Jul 2022 Initial release Serial number 1001 and higher 7716 Prepared MPB DGB Checked A...

Page 3: ...ss 3 2 3 Unpacking and Inspecting Equipment 3 2 3 1 Warranty 3 2 4 Installation Procedures 3 2 4 1 Installation Limitations 3 2 4 2 Cabling and Wiring 3 2 4 3 Mechanical Installation 4 2 4 6 Post Installation Checks 4 2 5 Installation Kit 4 2 5 1 Recommended Crimp tools 4 2 6 Installation Drawings 4 SECTION 3 OPERATION 5 3 1 Introduction 5 3 2 Front Panel Connectors 5 3 2 1 USB C Power Output 5 3 ...

Page 4: ...upply up to 45 Watts 1 3 Inputs and Outputs Refer to the JA74 410 connector map for the mating connector designators and contact assignments for the input and bi directional signals 1 3 1 Inputs Name Qty Type POWER INPUT 1 Power CC1 1 CC1 input CC2 1 CC2 input 1 3 2 Output Name Qty Type 5VDC 1 USB power output V BUS 4 USB power output 1 3 3 Bi Directional Name Qty Type D 1 Charge sense D 1 Charge ...

Page 5: ...t rated voltage 5 Vdc 5 9 Vdc 5 12 Vdc 5 15 Vdc 5 20 Vdc 5 Ripple Short circuit 1 4 2 Mechanical Specifications Height Behind panel depth not including connectors Width Weight Enclosure Faceplate Connector 3 J1 Main J2 USB C J3 USB A Mounting Bonding Installation kit part number 5 mVpp for 5 V output 9 mVpp for 9 V output 12 mVpp for 12 V output 15 mVpp for 15 V output 20 mVpp for 20 V output 1 mi...

Page 6: ...se misuse accident or unauthorized alteration or repairs THIS WARRANTY IS VOID IF THE PRODUCT IS NOT INSTALLED BY AN AUTHORIZED JAC DEALER If the on line warranty card is not completed the product will be warranted from the date of manufacture Contact JAC for return authorization and for any questions regarding this warranty and how it applies to your unit s JAC is the final arbiter concerning war...

Page 7: ...and confirm normal operation of all functions of the JA74 Refer to Section 3 Operation for specific operational details When all performance checks are satisfied complete the necessary regulatory documentation before releasing the aircraft for service Refer to Appendix B 2 5 Installation Kit The kit required to install this unit is not included with the unit The installation kit Part INST JA74 con...

Page 8: ...le with an auto adjustable supply which can deliver 5 Vdc 3 A 9 Vdc 3 A 12 Vdc 3 A 15 Vdc 3 A or 20 Vdc 2 25 A for charging cell phones and similar devices 3 2 2 USB A Power Output This Power Output is a USB Type A connector Note The USB A port is not designed to be used for data transfer This connector is provided to supply 5 Vdc up to 2 1 Amps for charging cell phones and similar devices 3 3 Com...

Page 9: ...nstallation Drawings A1 Introduction The drawings necessary for installation and troubleshooting of the JA74 410 USB A and USB C Charger are in this Appendix as listed below A2 Installation Drawings DOCUMENT Rev JA74 410 Connector Map A JA74 410 Interconnect A JA74 410 Mechanical Installation A ...

Page 10: ... 9 PIN FEMALE DMIN MATING CONNECTOR VIEW IS FROM REAR OF MATING CONNECTOR P3 USB TYPE A MALE MATING CONNECTOR 5V D D 4 3 2 1 View is from front of mating connector USB A Connector GROUND Main Connector P2 USB TYPE C MALE MATING CONNECTOR USB C Connector B2 B1 View is from front of mating connector B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 A2 A1 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 SPARE 6 SPARE 7 SPARE 5 V BUS...

Page 11: ...AWG MIN UNLESS OTHERWISE SPECIFIED UNSHIELDED WIRE SHOULD BE SELECTED PER FAA AC43 13 1B CHANGE 1 PARA 11 76 TO 11 78 WIRE TYPES SHOULD BE IN ACCORDANCE WITH MIL W 22759 AS DESCRIBED IN FAA AC43 13 1B CHANGE 1 PARA 11 85 AND 11 86 AND LISTED IN TABLE 11 11 OR 11 12 ALL SHIELDED CABLE SHOULD BE IN ACCORDANCE WITH MIL DTL 27500 REVISION H OR LATER CONNECTION TO AIRFRAME GROUND SHOULD BE MADE WITH 22...

Page 12: ...POWER GROUND 6 GROUND RETURN A1 P2 USB TYPE C MALE MATING CONNECTOR VBUS A4 CC1 A5 VBUS A9 22 AWG 22 AWG JA74 410 USB C J2 J1 CHARGEABLE USB DEVICE 2 3 GROUND RETURN A12 GROUND RETURN B1 VBUS B4 CC2 B5 VBUS B9 GROUND RETURN B12 GROUND RETURN A1 VBUS A4 CC1 A5 VBUS A9 GROUND RETURN A12 GROUND RETURN B1 VBUS B4 CC2 B5 VBUS B9 GROUND RETURN B12 5V 1 P3 USB TYPE A MALE MATING CONNECTOR D 2 D 3 GROUND ...

Page 13: ...O 1 1 SHEET JA74 410 PART NO TITLE DRAWING NOT TO SCALE TO JUPITER AVIONICS CORP APPROVED CHECKED TAT PREPARED N A N A MATERIAL FINISH NCAGE CODE L00N3 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES ANGLES ARE IN DEGREES TOLERANCES 1 DEC PLACE 0 1 2 DEC PLACE 0 01 3 DEC PLACE 0 005 ANGLES USB A and USB C Charger J2 J3 1 125in MAX 28 6mm MAX 5 75in MAX 146 1mm MAX 5 46in MAX 138 7mm MAX 0 45in...

Page 14: ...Rev A Page B1 JA74 410 USB A and USB C Charger Installation and Operating Manual Appendix B Installation Documents ...

Page 15: ... Maintenance of the JA74 410 USB A and USB C Charger is on condition only Periodic maintenance of the JA74 410 is not required The following sample Instructions for Continued Airworthiness ICA provides assistance in preparing ICA for the Jupiter Avionics JA74 410 unit installation as part of a Type Certificate TC or Supplemental Type Certificate STC project to comply with CAR STD AWM 523 527 525 5...

Page 16: ...ual If the unit is removed and reinstalled a functional check of the equipment should be conducted 8 Diagrams Refer to Appendix A of this manual the JA74 410 Installation and Operating Manual for installation drawings and interconnect examples 9 Special Inspection Requirements N A 10 Application of Protective Treatments N A 11 Data Relative to Structural Fasteners JA74 410 and appropriate mounting...

Reviews: