Table 58: List of Interface Cards for Upgrade
Replacement Cards for Upgrade
Cards to Replace
SRX5K-MPC and MICs
SRX5K-40GE-SFP
SRX5K-MPC and MICs
SRX5K-4XGE-XFP
SRX5K-MPC and MICs
SRX5K-FPC-IOC
SRX5K-RE-1800X4
SRX5K-RE-13-20
SRX5K-SCBE
SRX5K-SCB
SRX5K-SCB3
SRX5K-SCBE
•
Verify that both services gateways in the cluster are running the same Junos OS versions; release
12.1X47-D15 or later for SRX5K-SCBE with SRX5K-RE-1800X4 and 15.1X49-D10 or later for
SRX5K-SCB3 with SRX5K-RE-1800X4. For more information on cards supported on the services gateways
see Cards Supported on SRX5400, SRX5600, and SRX5800 Services Gateways.
For more information about unified in-service software upgrade (unified ISSU), see
Devices in a Chassis Cluster Using an ISSU
.
To perform an ISHU:
1. Export the configuration information from the secondary node to a USB or an external storage device.
For more information about mounting the USB on the device, refer to KB articles KB12880 and KB12022
from the
.
2. Power off the secondary node.
See, Powering Off the SRX5400 Services Gateway,
“Powering Off the SRX5600 Services Gateway” on
, or Powering Off the SRX5800 Services Gateway.
3. Disconnect all the interface cards from the chassis backplane by pulling them out of the backplane by
6” to 8” (leaving cables in place).
4. Replace the SRX5K-SCBs with SRX5K-SCBEs, or SRX5K-SCBEs with SRX5K-SCB3s and
SRX5K-RE-13-20s with SRX5K-RE-1800X4s based on the chassis specifications.
5. Power on the secondary node.
See:
299
Summary of Contents for SRX5600
Page 1: ...SRX5600 Services Gateway Hardware Guide Published 2020 02 14 ...
Page 23: ......
Page 105: ...LEDs 106 ...
Page 114: ...Figure 51 SRX5K MPC g030309 MPC empty 115 ...
Page 124: ...Port and Interface Numbering 125 ...
Page 130: ...Port and Interface Numbering 131 ...
Page 156: ......
Page 185: ......
Page 193: ...Figure 84 Installing the Front Mounting Hardware for a Four Post Rack or Cabinet 196 ...
Page 239: ......
Page 285: ...c Upload the configuration to RE2 from the USB device 288 ...
Page 372: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5600 377 ...
Page 373: ......
Page 407: ......
Page 420: ...423 ...
Page 423: ...Restricted Access Area Warning 426 ...
Page 430: ...433 ...
Page 443: ...Jewelry Removal Warning 446 ...
Page 446: ...Operating Temperature Warning 449 ...
Page 456: ...DC Power Disconnection Warning 459 ...
Page 460: ...DC Power Wiring Sequence Warning 463 ...
Page 463: ...DC Power Wiring Terminations Warning 466 ...
Page 466: ...DC Power Disconnection Warning 469 ...
Page 470: ...DC Power Wiring Sequence Warning 473 ...