Table 17: AC Power Supply Electrical Specifications (continued)
Specification
Item
High-Capacity
Standard-Capacity
13 A @ 240 VAC maximum per AC input (26 A
per power supply when two AC inputs are used)
11 A @ 240 VAC maximum
AC input current rating
Operating range: 200 to 240 VAC
AC input voltage
50 to 60 Hz
AC input line frequency
~88%
NOTE:
This value is at full load and nominal voltage.
Efficiency
Table 18: AC Power System Specifications
High-Capacity
Normal-Capacity
Item
One AC input for each
power supply
Two AC inputs for each
power supply
2+2
2+2
3+1
Redundancy
1700 W
4100 W
1700 W
Output power (maximum) per
supply
3400 W
8200 W
5100 W
Output power (maximum) per
system
AC Power Cord Specifications for the SRX5800 Services Gateway
Each AC power supply has a single AC appliance inlet located in the chassis directly above the power
supply that requires a dedicated AC power feed. Most sites distribute power through a main conduit that
leads to frame-mounted power distribution panels, one of which can be located at the top of the rack that
houses the services gateway. An AC power cord connects each power supply to the power distribution
panel.
The services gateway is not shipped with AC power cords. You must order power cords separately using
the model number shown in
. The C19 appliance coupler at the female end of the
cord inserts into the AC appliance inlet coupler, type C20 (right angle) as described by International
55
Summary of Contents for SRX 5800
Page 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Page 23: ......
Page 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Page 111: ...LEDs 112 ...
Page 121: ...Port and Interface Numbering 122 ...
Page 127: ...Port and Interface Numbering 128 ...
Page 161: ......
Page 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Page 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Page 205: ......
Page 261: ......
Page 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Page 365: ...Figure 143 Installing an SPC 366 ...
Page 367: ...368 ...
Page 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Page 423: ......
Page 457: ......
Page 473: ...475 ...
Page 476: ...Restricted Access Area Warning 478 ...
Page 483: ...485 ...
Page 496: ...Jewelry Removal Warning 498 ...
Page 499: ...Operating Temperature Warning 501 ...
Page 509: ...DC Power Disconnection Warning 511 ...
Page 513: ...DC Power Wiring Sequence Warning 515 ...
Page 516: ...DC Power Wiring Terminations Warning 518 ...
Page 519: ...DC Power Disconnection Warning 521 ...
Page 523: ...DC Power Wiring Sequence Warning 525 ...