Table 42: Chassis Alarm Messages for QFX5220
Recommended Action
CLI Message
Alarm Type
Component
Install fan modules in the slots where
they are absent.
Fan Tray fan-tray-number Absent
Red (major)
Fans
Remove and check fan module for
obstructions. Reinsert the fan module.
If the problem persists, replace the
fan module.
Fan Tray fan-tray-number Failure
Check the environmental conditions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the equipment)
do not affect the temperature sensor.
If the condition persists, the device
might shut down.
sensor-location Temp Sensor Too Hot
Remove and check fan module for
obstructions. Reinsert the fan module.
If the problem persists, check the
system log for the message related to
the sensor and report the message to
customer service.
FAN fan-number Fan Sensor Fail
Yellow (minor)
Check the environmental conditions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the equipment)
do not affect the temperature sensor.
sensor-location Temp Sensor Too
Warm
Install a power supply into the empty
slot and ensure the power supply is
powered.
PEM pem-number Not Powered
Red (major)
Power Supplies
182
Summary of Contents for QFX5220
Page 1: ...QFX5220 Switch Hardware Guide Published 2019 11 07 ...
Page 18: ......
Page 77: ......
Page 107: ......
Page 148: ......
Page 172: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the QFX5220 179 ...
Page 173: ......
Page 182: ......
Page 206: ...Restricted Access Warning 213 ...
Page 221: ...Jewelry Removal Warning 228 ...
Page 224: ...Operating Temperature Warning 231 ...
Page 234: ...DC Power Disconnection Warning 241 ...
Page 238: ...DC Power Wiring Sequence Warning 245 ...