Figure 47: Connecting a Grounding Cable to a QFX5120-32C Switch
g051126
3. Secure the grounding lug to the protective earthing terminal with the washers and screws.
4. Dress the grounding cable and ensure that it does not touch or block access to other switch components.
WARNING:
Ensure that the cable does not drape where people could trip over it.
Connecting AC Power to a QFX5120 Switch
The QFX5120 is shipped with two 650 W power supplies pre-installed. Each power supply is a
hot-removable and hot-insertable field-replaceable unit (FRU) when the second power supply is installed
and running. You can install replacement power supplies in the two slots next to the fan modules without
powering off the switch or disrupting switch functions.
Ensure that you have a power cord appropriate for your geographical location available to connect AC
power to the switch.
Before you begin connecting AC power to the switch:
•
Ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage
(see
“Prevention of Electrostatic Discharge Damage” on page 191
•
Ensure that you have connected the switch chassis to earth ground.
99
Summary of Contents for QFX5120 Series
Page 1: ...QFX5120 Switch Hardware Guide Published 2019 10 15 ...
Page 18: ......
Page 62: ......
Page 87: ......
Page 116: ......
Page 138: ...5 CHAPTER Troubleshooting Hardware Troubleshooting QFX5120 Components 145 ...
Page 139: ......
Page 145: ......
Page 163: ...Restricted Access Warning 169 ...
Page 178: ...Jewelry Removal Warning 184 ...
Page 181: ...Operating Temperature Warning 187 ...
Page 190: ...DC Power Disconnection Warning 196 ...
Page 194: ...DC Power Wiring Sequence Warning 200 ...