Configuring a Nonprovisioned Virtual Chassis Fabric
CAUTION:
Configure your Virtual Chassis Fabric (VCF) using autoprovisioning or
preprovisioning unless you have a compelling reason to use nonprovisioned
configuration. You can configure all aspects of a VCF using autoprovisioned or
preprovisioned configuration. The process for autoprovisioning your VCF is described
in
“Autoprovisioning a Virtual Chassis Fabric” on page 368
and the process for
preprovisioning your VCF is described in
“Preprovisioning a Virtual Chassis Fabric” on
.
Nonprovisioned VCF configuration is highly discouraged. Nonprovisioned VCF
configuration should only be used by VCF experts in specialized scenarios.
A nonprovisioned VCF is the configuration mode used when a VCF has not been configured into
autoprovisioned or preprovisioned mode.
In a nonprovisioned VCF, you configure the device roles by setting the primary-role priority value of each
device. If no primary-role priority values are set, a algorithm process runs and selects the role for each
device.
You must manually configure all Virtual Chassis ports (VCPs) in a nonprovisioned VCF. The automatic VCP
conversion feature, which automatically configures supported 10-Gbps SFP+ links and 40-Gbps QSFP+
links into VCPs on autoprovisioned and preprovisioned VCFs, is not supported on nonprovisioned VCFs.
Update all devices to the same version of Junos OS that supports VCF. See Installing Software Packages on
QFX Series Devices or Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine
(CLI Procedure).
CAUTION:
QFX5100 switches running a Junos OS image that includes “-qfx-5-” in
the software package filename must be upgraded to a package filename that includes
“-qfx-5e-” before being added to a QFX5110 Virtual Chassis. See Upgrading a QFX5100
Switch with a USB Device to Join a QFX5110 Virtual Chassis or Virtual Chassis Fabric.
To configure a nonprovisioned VCF:
1. Power on the devices.
2. Configure each individual device into fabric mode. If needed for a mixed VCF, configure the devices
into mixed mode.
Reboot each device to complete this configuration step.
380
Summary of Contents for QFX3500
Page 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Page 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Page 229: ...205...
Page 238: ...Unterminated Fiber Optic Cable Warning 214...
Page 246: ...Restricted Access Warning 222...
Page 249: ...225...
Page 257: ...Jewelry Removal Warning 233...
Page 260: ...Operating Temperature Warning 236...
Page 271: ...DC Power Disconnection Warning 247...
Page 275: ...DC Power Wiring Sequence Warning 251...
Page 278: ...DC Power Wiring Terminations Warning 254...
Page 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Page 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Page 565: ...Table 105 System Information continued Description Field Inventory details 541...