background image

PTX10003-80C and PTX10003-160C
Fixed Packet Transport Router Hardware
Guide

Published

2019-10-03

Summary of Contents for PTX10003-160C

Page 1: ...PTX10003 80C and PTX10003 160C Fixed Packet Transport Router Hardware Guide Published 2019 10 03...

Page 2: ...port Router Hardware Guide Copyright 2019 Juniper Networks Inc All rights reserved The information in this document is current as of the date on the title page YEAR 2000 NOTICE Juniper Networks hardwa...

Page 3: ...e 24 PTX10003 System Software 24 PTX10003 Fixed Configuration Router Specifications 25 PTX10003 Port Panel 26 PTX10003 160C Port Panel 26 PTX10003 80C Port Panel 27 Understanding QSFP DD Interfaces an...

Page 4: ...n Modules 46 PTX10003 Chassis Airflow 47 Fan Module Status and LED Description 48 PTX10003 Power System 50 PTX10003 AC HVDC Power Supply Description 50 PTX10003 AC HVDC Power Supply LED 52 PTX10003 AC...

Page 5: ...Connectors 79 24 Fiber MPO Connectors 83 LC Duplex Connectors 84 Understanding Fiber Optic Cable Signal Loss Attenuation and Dispersion 85 Signal Loss in Multimode and Single Mode Fiber Optic Cable 8...

Page 6: ...ting the PTX10003 105 Connect the PTX10003 to Power 109 Connecting the PTX10003 to Ground 110 Connecting AC Power to the PTX10003 112 Connecting DC Power to the PTX10003 114 Connecting the PTX10003 80...

Page 7: ...om the PTX10003 80C 143 Installing a Transceiver in the PTX10003 80C 146 Disconnecting a Fiber Optic Cable from a PTX10003 80C 148 Connecting a Fiber Optic Cable to a PTX10003 80C 149 Maintaining Fibe...

Page 8: ...es and Warnings 175 Definitions of Safety Warning Levels 176 Qualified Personnel Warning 178 Warning Statement for Norway and Sweden 179 Fire Safety Requirements 179 Fire Suppression 179 Fire Suppress...

Page 9: ...ge Damage 205 AC Power Electrical Safety Guidelines 207 AC Power Disconnection Warning 208 DC Power Electrical Safety Guidelines 209 DC Power Copper Conductors Warning 210 DC Power Disconnection Warni...

Page 10: ...Taiwan 227 United States 227 x...

Page 11: ...cal documentation see the product documentation page on the Juniper Networks website at https www juniper net documentation If the information in the latest release notes differs from the information...

Page 12: ...From the HTML or PDF version of the manual copy a configuration example into a text file save the file with a name and copy the file to a directory on your routing platform For example copy the follo...

Page 13: ...platform commit file ex script snippet xsl 2 Move to the hierarchy level that is relevant for this snippet by issuing the following configuration mode command edit user host edit system scripts edit...

Page 14: ...text and syntax conventions used in this guide Table 2 Text and Syntax Conventions Examples Description Convention To enter configuration mode type the configure command user host configure Represent...

Page 15: ...b default metric metric Encloses optional keywords or variables angle brackets broadcast multicast string1 string2 string3 Indicates a choice between the mutually exclusive keywords or variables on ei...

Page 16: ...he Juniper Networks TechLibrary site and do one of the following Click the thumbs up icon if the information on the page was helpful to you Click the thumbs down icon if the information on the page wa...

Page 17: ...tation Find solutions and answer questions using our Knowledge Base https kb juniper net Download the latest versions of software and review release notes https www juniper net customers csc software...

Page 18: ...R Overview PTX10003 System Overview 21 PTX10003 Port Panel 26 PTX10003 Field Replaceable Units Panel 36 PTX10003 Management Panel 40 PTX10003 Cooling System Description and Airflow 46 PTX10003 Power S...

Page 19: ......

Page 20: ...wo models with differing capacities are available The PTX10003 160C supports 16 Tbps throughput and the PTX10003 80C supports 8 Tbps throughput each in a compact 3 U footprint TIP For information abou...

Page 21: ...s you need Interoperability The PTX10003 provides seamless interoperability with existing Juniper routing deployments PTX10003 160C The PTX10003 160C scales to 16 Tbps in a single chassis Operating in...

Page 22: ...iguration options with universal multirate QSFP DD for 100GE 400GE FlexE to support 160 QSFP 10 GbE ports 40 QSFP 40 GbE ports 80 QSFP28 100 GbE ports 32 QSFP28 DD 200 GbE ports or 16 QSFP56 DD 400 Gb...

Page 23: ...gh density 10 GbE 40 GbE 100 GbE 200 GbE and 400 GbE PTX10003 System Software The PTX10003 runs Junos OS Evolved which provides Layer 2 and Layer 3 switching routing and security services Junos OS Evo...

Page 24: ...ntel Broadwell CPU with 12 Cores CPU 64 Gigabit SDRAM 64 Gigabit SDRAM RAM 200 GBx2 200 GBx2 SSD 2500 W AC HVDC 8525 BTU hr 4000 W AC HVDC 13640 BTU hr Maximum power draw 1600 W AC HVDC 5456 BTU hr 31...

Page 25: ...uration the PTX10003 160C features flexible interface configuration options with universal multi rate double density Quad Small Form factor Pluggable QSFP DD optics The port panel has 80 optical inter...

Page 26: ...f five ports Each port group is controlled by two PFEs PTX10003 80C Port Panel Operating in a fixed core router configuration the PTX10003 80C features flexible interface configuration options with un...

Page 27: ...Plus ASIC contains two logically independent PFEs which can provide 400 Gbps throughput Each QSFP DD port group is controlled by two PFEs with the middle QSFP DD interface port 2 and port 7 being shar...

Page 28: ...are other ways to attain the maximum system throughput The 400 Gbps optics can be used in combination with 100 Gbps optics and 200 Gbps optics as shown in the following examples Allowable QSFP DD Inte...

Page 29: ...0 16 400 Gbps 1x400 Gbps QSFP56 DD 16 64 100 Gbps 4x100 Gbps Examples of PTX10003 QSFP DD Configurations By default all PTX10003 QSFP DD interfaces are configured for a data rate of 2x100 Gbps You can...

Page 30: ...G QSFP56 DD 4 x 10G QSFP 1 x 400G QSFP56 DD 0 1 2 3 4 4 x 10G QSFP With QSFP transceivers you can configure 10 Gbps or 40 Gbps interfaces on any port To attain the maximum 1 Tbps throughput for a port...

Page 31: ...10003 160C Allowable Port Numbers QSFP Transceiver Data Rate 40 80 0 9 QSFP28 1x100 Gbps 80 160 0 9 QSFP28 DD 2x100 Gbps 64 128 0 4 5 9 QSFP56 DD 4x100 Gbps Example Using Network Ports as 200 Gbps Eth...

Page 32: ...100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G 400G 100G With QSFP56 DD transceivers you can configur...

Page 33: ...ink status and activity See Table 10 on page 34 for how to interpret the port LEDs NOTE After you insert an optical transceiver the LINK UP LED flashes red and green during the first 60 seconds This m...

Page 34: ...m as 2x100 Gbps For more details see Understanding QSFP DD Interfaces and Configurations on page 28 You can channelize the Gigabit Ethernet interfaces on PTX10003 routers to create multiple independen...

Page 35: ...nnelize a port see Channelizing Interfaces on PTX10003 Routers SEE ALSO number of sub ports speed Ethernet fpc pic PTX10003 Field Replaceable Units Panel IN THIS SECTION PTX10003 160C FRU Panel 37 PTX...

Page 36: ...customers support tools updateinstallbase Failure to do so can result in significant delays if you need replacement parts This note does not apply if you replace existing components with the same type...

Page 37: ...ght to use license PTX10003 160C AC PTX10003 160C Base System AC PTX10003 160C base system with 160 100 GbE ports or 32 400 GbE ports 4 3000 W DC power supplies and 5 fan trays with standard tier righ...

Page 38: ...ure 10 on page 39 DC power supplies Figure 9 PTX10003 80C with AC HVDC Power Supplies g100261 2 1 1 3 4 3 1 ESD grounding point Chassis grounding points 4 2 Fan modules 3 Power supplies 2 Figure 10 PT...

Page 39: ...0C DC PTX10003 80C Base System DC JNP10003 80C spare chassis with 80 100 GbE ports or 16 400 GbE ports JNP10003 80C CHAS PTX10003 80C Chassis Spare Fan tray for 3 RU 8T and 16T fixed platforms JNP1000...

Page 40: ...s accessible through the console and out of band management ports on the management panel The management panel located in the upper right corner of the port panel has system status LEDs that alert you...

Page 41: ...t MNR minor alert 8 3 Four co axial input output IN OUT SMB connectors for external 1PPS and 5MHz 10MHz simultaneous I O bi directional timing BITS is not supported RJ 45 console UART CON port An opti...

Page 42: ...Used as chassis locator Blue off Beacon B Indicates which lane of optics corresponds to LED traffic indicator beneath optics Upper left corner LED corresponds to lane 0 proceeding clock wise lane 1 2...

Page 43: ...V 999 mV PE4 HMC VDD 0 9V 899 mV PE4 HMC AVDD 1 2V 1197 mV PE45 HMC AVDD 1 2V 1197 mV PE5 VDD Core 0 9V 949 mV PE5 AVDD Core 1 0V 1000 mV PE5 HMC VDD 0 9V 899 mV PE5 HMC AVDD 1 2V 1200 mV XMB VDD 3 3V...

Page 44: ...re 0 9V 950 mV PF0 AVDD Core 1 0V 999 mV PF1 VDD Core 0 9V 950 mV PF1 AVDD Core 1 0V 999 mV XDB VDD 3 3V 3298 mV XDB RT VDD 1 0V 999 mV MEZZ VDD 2 5V 2502 mV MEZZ PFE 1 5V 1502 mV MEZZ GEX 1 0V 999 mV...

Page 45: ...fans inside the power supplies A separate air plenum provides air circulation to the power supplies in the entrance at the top of the chassis There are no air filters in the PTX10003 Fans are field r...

Page 46: ...led for optimal operation of the router NOTE If a fan module fails and the remaining fan modules are unable to keep the PTX10003 within the desired temperature thresholds chassis alarms are raised and...

Page 47: ...Item Status RPM Measurement Tray 0 Fan 0 Absent Tray 0 Fan 1 Absent Tray 1 Fan 0 OK 5000 Spinning at normal speed Tray 1 Fan 1 OK 4400 Spinning at normal speed Tray 2 Fan 0 OK 5000 Spinning at normal...

Page 48: ...s possible Either the fan has failed or it is seated incorrectly To maintain proper airflow through the chassis leave the fan module installed in the chassis until you are ready to replace it Blinking...

Page 49: ...in each power supply provide front to back cooling The input voltages are as follows AC input voltage range 200 277 V 50 60 Hz DC input voltage range 40 VDC Min 72 VDC maximum CAUTION Do not mix AC H...

Page 50: ...is grounding points 2 4 2 Fan modules 5 AC HVDC Power supplies 4 Figure 17 PTX10003 80C FRU Panel AC HVDC Power Supplies Installed g100261 2 1 1 3 4 3 1 ESD grounding point Chassis grounding points 2...

Page 51: ...aining the PTX10003 Power Supplies on page 134 PTX10003 AC HVDC Power Supply LED Each PTX10003 AC HVDC power supply has a status LED on the power supply faceplate Refer to Figure 19 on page 52 Figure...

Page 52: ...gh power high current slow fan less than 1200 rpm Off Blinking There is no input power but the power supply module from another slot in the same system is on with 12 VSB active On Off The AC power cor...

Page 53: ...t 1 227 534 Capacity 3000 W maximum 3000 W PSM 2 Input 1 226 432 Capacity 3000 W maximum 3000 W PSM 3 Input 1 227 589 Capacity 3000 W maximum 3000 W Item Used W Routing Engine 0 147 CB 0 382 FPC 0 308...

Page 54: ...SM 1 Input 1 204 798 Capacity 3000 W maximum 3000 W PSM 2 Input 1 206 700 Capacity 3000 W maximum 3000 W user device show chassis power detail Chassis Power Input V Used W Total Power 1497 PDU 0 1497...

Page 55: ...60 Hz 47 Hz AC input line frequency PTX10003 AC Power Cord Specifications Detachable AC power cords are shipped with the chassis if you include them as part of your order The plug at the male end of t...

Page 56: ...3 16 A 250 VAC Argentina CBL JNP SG4 AU AS NZS 4417 15 A 250 VAC Australia and New Zealand g050616 CBL JNP SG4 BR NBR 14136 Type BR 3 16 A 250 VAC Brazil CBL JNP SG4 CH GB2099 16 A 250 VAC China g1003...

Page 57: ...VAC Israel CBL JNP SG4 IT CEI 23 16 16 A 250 VAC Italy g050751 CBL JNP SG4 C20 C20 to Anderson 3 5958p4 20 A 250 VAC North America CBL JNP SG4 US L Locking NEMA L6 20P 16 A 250 VAC North America CBL...

Page 58: ...round black is line and white is neutral For HVDC the black and white wires are not polarity sensitive The black wire can be positive or neutral and the white wire can be positive or negative PTX10003...

Page 59: ...2 Fan modules 5 DC power supplies 4 Figure 21 PTX10003 80C FRU Panel DC Power Supplies Installed g100262 1 1 3 4 2 3 1 ESD grounding point Chassis grounding points 2 4 2 Fan modules 3 DC power supplie...

Page 60: ...witch CAUTION To avoid electrical injury carefully follow instructions in Maintaining the PTX10003 Power Supplies on page 134 PTX10003 DC Power Supply LED Each PTX10003 DC power supply has a status LE...

Page 61: ...amber The power supply is uploading firmware Blinking green PTX10003 DC Input Current Selector DIP Switch The PTX10003 DC power supply can operate with an input current of 80 A or 60 A You select the...

Page 62: ...cy for the PTX10003 the power supply modules must be connected to an 80 A power source and the input current selector DIP switch on the power supply must be set to 80 A For the PTX10003 80C the maximu...

Page 63: ...black is line and white is neutral The wires are labeled and to indicate their polarity CAUTION You must ensure that power connections maintain the proper polarity WARNING For field wiring connections...

Page 64: ...ou supply A cable with an incorrectly attached lug can damage the PTX10003 Viewing Power Statistics You can get additional information about the status of the power modules using the show chassis powe...

Page 65: ...vice show chassis power detail Chassis Power Input V Used W Total Power 176 PDU 0 176 PSM 0 Input 1 51 2 Capacity 3000 W maximum 3000 W PSM 1 Input 1 51 53 Capacity 3000 W maximum 3000 W PSM 2 Input 1...

Page 66: ...Input V Used W Total Power 1558 PDU 0 1558 PSM 1 Input 1 203 777 Capacity 3000 W maximum 3000 W PSM 2 Input 1 204 781 Capacity 3000 W maximum 3000 W root re0 show chassis power detail Chassis Power I...

Page 67: ...750 W 3250 W remaining Actual usage 1563 W Total system capacity 6000 W maximum 6000 W Total remaining power 3250 W RELATED DOCUMENTATION PTX10003 System Overview 21 Prevention of Electrostatic Discha...

Page 68: ...Preparation and Specifications PTX10003 Site Preparation Checklist 71 PTX10003 Site Guidelines and Requirements 72 PTX10003 Network Cable and Transceiver Planning 78 PTX10003 Management Cable Specifi...

Page 69: ......

Page 70: ...ation site PTX10003 Power System on page 50 Calculate the power consumption and requirements Rack PTX10003 Rack Requirements on page 76 Verify that your rack meets the minimum requirements for the ins...

Page 71: ...Warning 183 Ramp Warning 185 Rack Mounting and Cabinet Mounting Warnings 185 Grounded Equipment Warning 190 PTX10003 Site Guidelines and Requirements IN THIS SECTION PTX10003 Environmental Requirement...

Page 72: ...ion Table 22 PTX10003 Environmental Tolerances Tolerance Description No performance degradation up to 6000 feet 1828 8 meters Altitude Normal operation ensured in relative humidity range of 5 through...

Page 73: ...ions that require a separate grounding conductor to the chassis the PTX10003 must be adequately grounded before power is connected to ensure proper operation and to meet safety and electromagnetic int...

Page 74: ...than the input wire of each power supply Minimum recommendations are 4 AWG 8 4 mm stranded wire 60 C wire or as permitted by local code SEE ALSO Connect the PTX10003 to Power 109 PTX10003 Clearance R...

Page 75: ...03 chassis Table 23 Physical Specifications for the PTX10003 PTX10003 80C PTX10003 160C Hardware 88 lb 40 kg 110 lb 50 kg Weight 17 4 x 5 25 x 31 in 44 2 x 13 3 x 78 7 cm 17 4 x 5 25 x 31 in 44 2 x 13...

Page 76: ...tandard for equipment practice document numbers ETS 300 119 1 through 119 4 published by the European Telecommunications Standards Institute http www etsi org The horizontal spacing between the rails...

Page 77: ...ur Juniper device by using the Hardware Compatibility Tool In addition to transceiver and connection type the optical and cable characteristics where applicable are documented for each transceiver The...

Page 78: ...ypes of cables used with 12 fiber MPO connectors on Juniper Networks devices patch cables with MPO connectors on both ends and breakout cables with an MPO connector on one end and four LC duplex conne...

Page 79: ...R4 to 100GBASE SR4 You can also connect 4x10GBASE LR or 4x10GBASE SR transceivers by using patch cables for example 4x10GBASE LR to 4x10GBASE LR or 4x10GBASE SR to 4x10GBASE SR instead of breaking the...

Page 80: ...SFP transceivers for example 4x10GBASE LR to 10GBASE LR or 4x10GBASE SR to 10GBASE SR SFP transceivers The breakout cable is constructed out of a 12 fiber ribbon fiber optic cable The ribbon cable sp...

Page 81: ...ctor Pin Tx on LC Duplex 1 1 Tx on LC Duplex 2 2 Tx on LC Duplex 3 3 Tx on LC Duplex 4 4 Unused 5 Unused 6 Unused 7 Unused 8 Rx on LC Duplex 4 9 Rx on LC Duplex 3 10 Rx on LC Duplex 2 11 Rx on LC Dupl...

Page 82: ...y up MTP12 FF S3M 3 m MTP12 FF S5M 5 m MTP12 FF S10M 10 m MTP 4LC M1M 1 m MMF OM3 Female MPO PC key up to four LC UPC duplex 12 ribbon breakout MTP 4LC M3M 3 m MTP 4LC M5M 5 m MTP 4LC M10M 10 m MTP 4L...

Page 83: ...ctor is required to mate with the module Ferrule finish shall be flat polished interface that is compliant with IEC 61754 7 Alignment key is key up The optical interface must meet the requirement FT 1...

Page 84: ...into the multimode fiber which reflects the light at different angles Light rays travel in jagged lines through a multimode fiber causing signal dispersion When light traveling in the fiber core radia...

Page 85: ...the maximum bit rate and link length For single mode transmission modal dispersion is not a factor However at higher bit rates and over longer distances chromatic dispersion rather than modal dispers...

Page 86: ...dB and decibels referred to one milliwatt dBm P B P T P R P B 15 dBm 28 dBm P B 13 dB Calculating Power Margin for Fiber Optic Cable After calculating a link s power budget you can calculate the powe...

Page 87: ...es 0 5 dB per splice or 1 dB as well as higher order mode losses 0 5 dB The power margin P M is calculated as follows P M P B LL P M 13 dB 2 km 1 dB km 5 0 5 dB 2 0 5 dB 0 5 dB P M 13 dB 2 dB 2 5 dB 1...

Page 88: ...cables that connect the PTX10003 to a management device NOTE The PTX10003 also has an SFP management port that supports transceivers that use fiber optic cables See Determining Transceiver Support for...

Page 89: ...smit receive data pair 2 TRP2 6 Transmit receive data pair 4 TRP4 7 Transmit receive data pair 4 TRP4 8 PTX10003 Console Port Connector Pinouts The console port labeled CON is an RS 232 serial interfa...

Page 90: ...rrier detect DCD Input 7 Clear to send CTS Input 8 PTX10003 SFP Port Connector Pinouts Table 33 SFP Network Port Connector Pinout Information Description Signal Pin Module transmitter ground VeeT 1 Mo...

Page 91: ...transmitter 3 3 V supply VccT 16 Module transmitter ground VeeT 17 Transmitter noninverted data input TD 18 Transmitter inverted data input TD 19 Module transmitter ground VeeT 20 PTX10003 SFP Port Co...

Page 92: ...ground VeeR 11 Receiver inverted data output RD 12 Receiver noninverted data output RD 13 Module receiver ground VeeR 14 Module receiver 3 3 V supply VccR 15 Module transmitter 3 3 V supply VccT 16 M...

Page 93: ...work Port Connector Pinout Information continued Signal Pin GND 4 TX4n 5 TX4p 6 GND 7 ModSelL 8 LPMode_Reset 9 VccRx 10 SCL 11 SDA 12 GND 13 RX3p 14 RX3n 15 GND 16 RX1p 17 RX1n 18 GND 19 GND 20 RX2n 2...

Page 94: ...Reserved 31 GND 32 TX3p 33 TX3n 34 GND 35 TX1p 36 TX1n 37 GND 38 PTX10003 USB Port Specifications The following Juniper Networks USB flash drives have been tested and are officially supported for the...

Page 95: ...s Technical Assistance Center JTAC can provide only limited support for issues related to unsupported hardware We strongly recommend that you use only supported USB flash drives CAUTION Remove the USB...

Page 96: ...99 Unpacking and Mounting the PTX10003 101 Connect the PTX10003 to Power 109 Connecting the PTX10003 80C to External Devices 120 Registering Products Mandatory for Validating SLAs 122 Performing the I...

Page 97: ......

Page 98: ...cking and Mounting the PTX10003 on page 101 2 Mount the PTX10003 in a rack See Unpacking and Mounting the PTX10003 on page 101 3 For installations that require a separate grounding conductor to the ch...

Page 99: ...is Lifting Guidelines The weight of a fully loaded PTX10003 160C is approximately 110 lb 50 kg The weight of a fully loaded PTX10003 80C is approximately 88 lb 40 kg Observe the following guidelines f...

Page 100: ...d in a cardboard carton secured with foam packing material The carton also contains an accessory kit CAUTION PTX10003 routers are maximally protected inside the shipping carton Do not unpack the PTX10...

Page 101: ...RJ to RJ 45 serial port adapter straight through cable ESD wrist strap with cable Cable management assembly Road Map card For the PTX10003 80C Chassis with three fan modules and two power supplies ins...

Page 102: ...ustable for racks with different depths The minimum distance the front and rear rack rails can be spaced apart is 26 in 66 04 cm front to back The maximum distance the front and rear rack rails can be...

Page 103: ...ext to the hot aisle 6 Remove the PTX10003 from the shipping carton see Unpacking the PTX10003 on page 101 7 Ensure that you have the following parts and tools available to mount the PTX10003 in a rac...

Page 104: ...recommend that you use a mechanical lift Mounting the PTX10003 1 Wrap and fasten one end of the ESD wrist strap around your bare wrist and connect the other end of the strap to the ESD point on the d...

Page 105: ...th the rack holes Have two people grasp both sides of the PTX10003 lift it and position it in the rack so that the front brackets on the front mounting rails are aligned with the rack holes 6 Continue...

Page 106: ...at the back of the rack See Figure 33 on page 107 and Figure 34 on page 107 Figure 33 PTX10003 Secured in Rack PTX10003 160C g100478 Figure 34 PTX10003 Secured in Rack PTX10003 80C g100306 8 Attach on...

Page 107: ...295 9 If you removed the power supplies and fan modules from the chassis before installation reinstall them Refer to Install the AC HVDC Power Supply in the PTX10003 on page 137 and Installing a Fan M...

Page 108: ...Connect the PTX10003 to Power IN THIS SECTION Connecting the PTX10003 to Ground 110 Connecting AC Power to the PTX10003 112 Connecting DC Power to the PTX10003 114 109...

Page 109: ...A cable with an incorrectly attached lug can damage the PTX10003 for example by causing a short circuit NOTE Mount the PTX10003 in the rack before attaching the grounding lug to the PTX10003 See Unpa...

Page 110: ...oint PTX10003 80C g100295 2 Secure the grounding lug to the protective earthing terminal with the washers and screws 3 Dress the grounding cable and ensure that it does not touch or block access to ot...

Page 111: ...l Accident on page 205 Ensure that you have taken the necessary precautions to prevent electrostatic discharge ESD damage see Prevention of Electrostatic Discharge Damage on page 205 Ensure that you h...

Page 112: ...r sources Insert the coupler end of the power cord into the AC power cord inlet on the AC power supply faceplate see Figure 39 on page 113 and Figure 40 on page 113 NOTE The coupler end of the power c...

Page 113: ...upply ready SEE ALSO PTX10003 Power System 50 Connecting DC Power to the PTX10003 The DC power supply in a PTX10003 is a hot removable and hot insertable field replaceable unit You can remove and repl...

Page 114: ...power For installations that require a separate grounding conductor to the chassis use the protective earthing terminal on the PTX10003 chassis to connect to the earth ground see Connecting the PTX10...

Page 115: ...nected to a dedicated power source outlet To connect DC power to a PTX10003 1 Attach an ESD grounding strap to your bare wrist and connect the strap to an approved site ESD grounding point 2 Ensure th...

Page 116: ...supply 5 Use a Phillips screwdriver to loosen the screw holding the cable manager latch to the power supply terminal block cover See Figure 42 on page 117 Figure 42 Loosening the Cable Manager Latch g...

Page 117: ...he DC power cable connector Do not overtighten the screws Applying excessive torque damages the terminal block and the wiring tray 10 Repeat Step 3 through Step 8 to connect the other DC power supplie...

Page 118: ...he Cable Manager Bracket g100296 13 Close the cable manager latch to hold the power cables in place See Figure 45 on page 119 and Figure 46 on page 120 WARNING Ensure that the power cables do not bloc...

Page 119: ...e 120 Connecting the PTX10003 80C to a Management Console 121 Connecting the PTX10003 80C to a Management Ethernet Device You can monitor and manage the PTX10003 80C by using a dedicated management ch...

Page 120: ...twork for out of band management see Figure 47 on page 121 1 Connect one end of the cable to one of the two management ports labeled MGMT on the PTX10003 80C 2 Connect the other end of the cable to th...

Page 121: ...the console port labeled CON on the PTX10003 2 Connect the other end of the Ethernet cable directly to a management console or console server Figure 48 Connecting the PTX10003 80C Directly to a Manage...

Page 122: ...sc management updateinstallbase jsp Performing the Initial Software Configuration for the PTX10003 You ll need to perform the initial configuration of the PTX10003 through the console port using the C...

Page 123: ...r the prompt to appear login root 3 Start the CLI root cli 4 Enter configuration mode root configure 5 Add a password to the root administration user account edit root set system root authentication p...

Page 124: ...ce edit root set system services telnet NOTE When Telnet is enabled you cannot log in to a PTX10003 through Telnet by using root credentials Root login is allowed only for SSH access 11 Commit the con...

Page 125: ...to one of the two management MGMT ports by following the instructions in Connecting the PTX10003 80C to a Management Ethernet Device on page 120 2 Shut down Junos OS Evolved from the external manageme...

Page 126: ...ly by pushing in the latch on the side of the power connector and gently pulling out the power plug from the power supply 6 Uncable the device before removing it from the rack Powering Off the DC Powe...

Page 127: ...event damage to the equipment caused by static discharge attach an electrostatic discharge ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis 4 Turn o...

Page 128: ...Maintaining Components Maintaining the PTX10003 Fan Modules 131 Maintaining the PTX10003 Power Supplies 134 Maintaining Transceivers and Fiber Optic Cables on the PTX10003 80C 143 Uninstalling the PTX...

Page 129: ......

Page 130: ...re you remove a fan module from a PTX10003 ensure that you have taken the necessary precautions to prevent electrostatic discharge ESD damage see Prevention of Electrostatic Discharge Damage on page 2...

Page 131: ...bag or on the antistatic mat placed on a flat stable surface Refer to Figure 50 on page 132 Figure 50 Removing a PTX10003 Fan Module g100284 Unlock tab to remove fan NOTE When a fan module is removed...

Page 132: ...ounding strap Phillips screwdriver number 1 To install a fan module in a PTX10003 see Figure 51 on page 133 1 To prevent damage to the equipment caused by static discharge attach an electrostatic disc...

Page 133: ...DC power supplies in the same chassis Replacing an AC HVDC Power Supply in the PTX10003 WARNING Turn off the power source before disconnecting the power cord to prevent damage to the power connector...

Page 134: ...the AC HVDC Power Supply from the PTX10003 135 2 Install the AC HVDC Power Supply in the PTX10003 137 Remove the AC HVDC Power Supply from the PTX10003 1 Place the antistatic bag or the antistatic ma...

Page 135: ...handle until it stops 6 Place one hand under the power supply to support it and slide it completely out of the chassis Take care not to touch power supply components pins leads or solder connections S...

Page 136: ...pply available 1 Wrap and fasten one end of the ESD wrist strap around your bare wrist and connect the other end of the strap to the ESD point on the device 2 If the power supply has protective plasti...

Page 137: ...cated power source outlet NOTE If you have a Juniper Care service contract register any addition change or upgrade of hardware components at https www juniper net customers support tools updateinstall...

Page 138: ...AUTION The DC power supply you are installing must use the same airflow direction as the fan trays installed in the router Labels on the power supply handle indicate the direction of airflow See PTX10...

Page 139: ...elease each of three cables from the power supply requires a standard screw driver 6 Grasp the power supply handle while pressing the release latch towards the power supply handle 7 Place one hand und...

Page 140: ...ective plastic wrap peel and remove the plastic wrap from all four sides of the power supply 3 Taking care not to touch power supply components pins leads or solder connections remove the power supply...

Page 141: ...power source outlet NOTE If you have a Juniper Care service contract register any addition change or upgrade of hardware components at https www juniper net customers support tools updateinstallbase...

Page 142: ...move and replace them without powering off the device or disrupting device functions NOTE After you remove a transceiver or when you change the media type configuration wait for 6 seconds for the inte...

Page 143: ...ceivers emit laser light that can damage your eyes WARNING Do not leave a fiber optic transceiver uncovered except when inserting or removing a cable The rubber safety cap keeps the port clean and pre...

Page 144: ...gently slide the transceiver approximately 0 5 in 1 3 cm straight out of the port CAUTION To prevent electrostatic discharge ESD damage to the transceiver do not touch the connector pins at the end o...

Page 145: ...JTAC can help you diagnose the source of the problem Your JTAC engineer might recommend that you check the third party optic or cable and potentially replace it with an equivalent Juniper Networks opt...

Page 146: ...t before installing a new transceiver 5 Using both hands carefully place the transceiver in the empty port The connectors must face the chassis CAUTION Before you slide the transceiver into the port e...

Page 147: ...have the following parts and tools available A rubber safety cap to cover the transceiver A rubber safety cap to cover the fiber optic cable connector To disconnect a fiber optic cable from an optica...

Page 148: ...LED Safety Guidelines and Warnings on page 190 To connect a fiber optic cable to an optical transceiver installed in a device WARNING Do not look directly into a fiber optic transceiver or into the en...

Page 149: ...t are installed in Juniper Networks devices To maintain fiber optic cables When you unplug a fiber optic cable from a transceiver place rubber safety caps over the transceiver and on the end of the ca...

Page 150: ...an installed PTX10003 perform the following procedure NOTE When you remove multiple devices from a rack remove the device at the top of the rack first and proceed to remove the rest of the devices fro...

Page 151: ...person uses the screwdriver to remove the front mounting screws that attach the router to the rack 2 Remove the PTX10003 from the rack 3 Use the screwdriver to remove the mounting screws that attach t...

Page 152: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the PTX10003 155...

Page 153: ......

Page 154: ...t Panel LEDs on page 42 PTX10003 Port LEDs on page 34 Fan Module Status and LED Description on page 48 CLI The CLI is the primary tool for controlling and troubleshooting hardware Junos OS Evolved rou...

Page 155: ...t Supported 2018 02 07 12 11 54 PST Major FPC0 PEM 0 Not Powered SEE ALSO Definitions of Safety Warning Levels 176 PTX10003 System Alarm Messages and Recommended Actions System alarms indicate a failu...

Page 156: ...d where fan number can be 1 2 or 3 Fan I2C Failure Remove and check the fan module for obstructions and then reinsert the fan module If the problem persists replace the fan module Fan fan number Not S...

Page 157: ...ation Temp Sensor Too Hot For information only Check environmental conditions and alarms on other devices Ensure that environmental factors such as hot air blowing around the equipment do not affect t...

Page 158: ...e cable if required If the problem cannot be resolved open a support case by using the Case Manager link at https www juniper net support or call 1 888 314 5822 toll free US and Canada or 1 408 745 95...

Page 159: ...6 CHAPTER Contacting Customer Support and Returning the Chassis or Components Contacting Customer Support 163 Returning the PTX10003 Chassis or Components 163...

Page 160: ......

Page 161: ...ephone be prepared to provide the following information Your existing service request number if you have one Details of the failure or problem Type of activity being performed on the device when the p...

Page 162: ...I you can list serial numbers for the router and some components with a CLI command If you do not have access to the CLI or if the serial number for the field replaceable unit does not appear in the c...

Page 163: ...x100G PIC 1 BUILTIN BUILTIN 4x400G 10x200G 20x100G Xcvr 5 REV 01 740 084673 SS1TY2A349003 QSFP28 DD 2X100GBASE SR4 Xcvr 6 REV 01 740 084673 2E1CY2A34901L QSFP28 DD 2X100GBASE SR4 Xcvr 8 REV 01 740 084...

Page 164: ...40G LR4 PIC 1 BUILTIN BUILTIN 4x400G 10x200G 20x100G Xcvr 0 REV 02 740 056706 1FCP8320016 QSFP 4x10G IR PSM4 Xcvr 1 REV 02 740 056706 1FCP831001V QSFP 4x10G IR PSM4 Xcvr 2 REV 02 740 056706 1FCP832400...

Page 165: ...077190 BCAH7469 JNP10003 Fan Tray Front to Back Airflow AFO Fan Tray 2 REV 07 750 077190 BCAH7525 JNP10003 Fan Tray Front to Back Airflow AFO Fan Tray 3 REV 07 750 077190 BCAH7622 JNP10003 Fan Tray Fr...

Page 166: ...sis Serial Number g100479 Serial number ID label Figure 65 Locating the PTX10003 80C Chassis Serial Number g100309 Serial number ID label Figure 66 Locating the PTX10003 AC Power Supply Serial Number...

Page 167: ...he serial number of the component For instructions see Locating the Serial Number on a PTX10003 Chassis or Component on page 164 2 Obtain a Return Material Authorization RMA number from the Juniper Te...

Page 168: ...llowing information Your existing service request number if you have one Serial number of the component Your name organization name telephone number fax number and shipping address Details of the fail...

Page 169: ...rials to learn about approved packing materials see Contacting Customer Support on page 163 Ensure that you have the following parts and tools available ESD grounding strap Antistatic bag one for each...

Page 170: ...instructions on obtaining an RMA number Packing a PTX10003 Component for Shipping CAUTION Do not stack PTX10003 components Return individual components in separate boxes if they do not fit together o...

Page 171: ...s 179 Installation Instructions Warning 181 Chassis and Component Lifting Guidelines 181 Restricted Access Warning 183 Ramp Warning 185 Rack Mounting and Cabinet Mounting Warnings 185 Grounded Equipme...

Page 172: ...ing 208 DC Power Electrical Safety Guidelines 209 DC Power Copper Conductors Warning 210 DC Power Disconnection Warning 211 DC Power Grounding Requirements and Warning 213 DC Power Wiring Sequence War...

Page 173: ...or manipulate wiring during electrical storms Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments Operate the device only when it is proper...

Page 174: ...s of safety warnings there are two Warning formats NOTE You might find this information helpful in a particular situation or you might overlook this important information if it was not highlighted in...

Page 175: ...befinden sich in einer Situation die zu einer K rperverletzung f hren k nnte Bevor Sie mit der Arbeit an irgendeinem Ger t beginnen seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahr...

Page 176: ...ention Tout installation ou remplacement de l appareil doit tre r alis par du personnel qualifi et comp tent Warnung Ger t nur von geschultem qualifiziertem Personal installieren oder auswechseln lass...

Page 177: ...n equipment be available in the event of a fire in the vicinity of the equipment and that all local fire safety and electrical codes and ordinances be observed when you install and operate your equipm...

Page 178: ...y equipment in a room in which a chemical fire extinguisher has been discharged is subject to premature failure and unreliable operation The equipment is considered to be irreparably damaged NOTE To k...

Page 179: ...s til str mkilden Aviso Leia as instru es de instala o antes de ligar o sistema sua fonte de energia Atenci n Ver las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n...

Page 180: ...or more people 70 5 lb 32 kg to 121 2 lb 55 kg Three or more people Above 121 2 lbs 55 kg Material handling systems such as levers slings lifts and so on must be used When this is not practical speci...

Page 181: ...Restricted Access Warning 183...

Page 182: ...es de s curit est sous le contr le de l autorit responsable de l emplacement Warnung Diese Einheit ist zur Installation in Bereichen mit beschr nktem Zutritt vorgesehen Ein Bereich mit beschr nktem Zu...

Page 183: ...n oprijplaat niet onder een hoek van meer dan 10 graden Varoitus l k yt sellaista kaltevaa pintaa jonka kaltevuus ylitt 10 astetta Attention Ne pas utiliser une rampe dont l inclinaison est sup rieure...

Page 184: ...rankerd Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert dient u het rek van onderen naa...

Page 185: ...sie unten im Gestell angebracht werden Bei Anbringung dieser Einheit in einem zum Teil gef llten Gestell ist das Gestell von unten nach oben zu laden wobei das schwerste Bauteil unten im Gestell anzu...

Page 186: ...ever ser instalado numa prateleira fixa estrutura do edificio Esta unidade dever ser montada na parte inferior da estante caso seja esta a nica unidade a ser montada Ao montar esta unidade numa estant...

Page 187: ...per Networks switch m ste installeras i en st llning som r f rankrad i byggnadens struktur Om denna enhet r den enda enheten p st llningen skall den installeras l ngst ned p st llningen Om denna enhet...

Page 188: ...t w hrend des normalen Betriebs an Erde gelegt ist Avvertenza Questa apparecchiatura deve essere collegata a massa Accertarsi che il dispositivo host sia collegato alla massa di terra durante il norma...

Page 189: ...When working around ports that support optical transceivers observe the following safety guidelines to prevent eye injury Do not look into unterminated ports or at fibers that connect to unknown sourc...

Page 190: ...aser produkt Varoitus Luokan 1 lasertuote Attention Produit laser de classe I Warnung Laserprodukt der Klasse 1 Avvertenza Prodotto laser di Classe 1 Advarsel Laserprodukt av klasse 1 Aviso Produto la...

Page 191: ...s Luokan 1 valodiodituote Attention Alarme de produit LED Class I Warnung Class 1 LED Produktwarnung Avvertenza Avvertenza prodotto LED di Classe 1 Advarsel LED produkt i klasse 1 Aviso Produto de cla...

Page 192: ...truments optiques Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen Ger ten pr fen Avvertenza Non fissare il raggio con gli occhi n usare strumenti ottici per osservarlo di...

Page 193: ...Vermeiden Sie es sich den Strahlungen auszusetzen und starren Sie nicht in die ffnungen Avvertenza Quando i cavi in fibra non sono inseriti radiazioni invisibili possono essere emesse attraverso l ap...

Page 194: ...SECTION Battery Handling Warning 197 Jewelry Removal Warning 198 Lightning Activity Warning 200 Operating Temperature Warning 201 Product Disposal Warning 203 While performing the maintenance activit...

Page 195: ...ichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Advarsel Det kan v re fare for eksplosjon hvis batteriet skiftes p feil m t...

Page 196: ...Jewelry Removal Warning 198...

Page 197: ...hmuck einschlie lich Ringe Ketten und Uhren abnehmen Metallgegenst nde erhitzen sich wenn sie an das Netz und die Erde angeschlossen werden und k nnen schwere Verbrennungen verursachen oder an die Ans...

Page 198: ...rissa l k yhdist tai irrota kaapeleita ukkosilmalla Attention Ne pas travailler sur le syst me ni brancher ou d brancher les c bles pendant un orage Warnung Arbeiten Sie nicht am System und schlie en...

Page 199: ...Operating Temperature Warning 201...

Page 200: ...einer Gegend betrieben werden in der die Umgebungstemperatur das empfohlene Maximum von 40 C berschreitet Um L ftungsverschlu zu verhindern achten Sie darauf da mindestens 15 2 cm lichter Raum um die...

Page 201: ...isia lakeja ja s nn ksi noudattaen Attention La mise au rebut d finitive de ce produit doit tre effectu e conform ment toutes les lois et r glementations en vigueur Warnung Dieses Produkt mu den gelte...

Page 202: ...other end of the strap around your bare wrist Failure to use an ESD grounding strap could result in damage to the device Install the device in compliance with the following local national and internat...

Page 203: ...he following actions in this order 1 Use caution Be aware of potentially hazardous conditions that could cause further injury 2 Disconnect power from the device 3 If possible send another person to ge...

Page 204: ...g strap is available touch the exposed bare metal of the device to ground yourself before handling the component Avoid contact between the component that is subject to ESD damage and your clothing ESD...

Page 205: ...ly a grounding type power outlet Do not circumvent this safety feature Equipment grounding must comply with local and national electrical codes You must provide an external certified circuit breaker 2...

Page 206: ...r in der N he von Netzger ten arbeiten ziehen Sie bei Wechselstromeinheiten das Netzkabel ab bzw Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori scollegare il cavo di alimentazione...

Page 207: ...0 NOTE Primary overcurrent protection is provided by the building circuit breaker This breaker must protect against excess currents short circuits and earth grounding faults in accordance with NEC ANS...

Page 208: ...uparijohtimia Attention Utilisez uniquement des conducteurs en cuivre Warnung Verwenden Sie ausschlie lich Kupferleiter Avvertenza Usate unicamente dei conduttori di rame Advarsel Bruk bare kobberledn...

Page 209: ...DC Power Disconnection Warning 211...

Page 210: ...le panneau de service du circuit en courant continu placer le disjoncteur en position ferm e OFF et l aide d un ruban adh sif bloquer la poign e du disjoncteur en position OFF Warnung Vor Ausf hrung...

Page 211: ...tor autom tico en posici n de Apagado OFF Varning Innan du utf r n gon av f ljande procedurer m ste du kontrollera att str mf rs rjningen till likstr mskretsen r bruten Kontrollera att all str mf rs r...

Page 212: ...emier et d connect e en dernier Warnung Der Erdanschlu mu bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden Avvertenza In fase di installazione dell unit eseguire...

Page 213: ...DC Power Wiring Sequence Warning 215...

Page 214: ...ord et d branch pour la derni re fois Warnung Die Stromzufuhr ist nur mit geeigneten Ring sen an das DC Netzteil anzuschliessen Die richtige Anschlusssequenz ist Erdanschluss zu Erdanschluss RTN zu RT...

Page 215: ...TN a RTN ent o 48 V a 48 V Ao desconectar a pot ncia a seq ncia apropriada da fia o 48 V a 48 V RTN a RTN moeu ent o para moer Anote que o fio terra deve sempre ser conectado primeiramente e desconect...

Page 216: ...DC Power Wiring Terminations Warning 218...

Page 217: ...eur Warnung Wenn Litzenverdrahtung erforderlich ist sind zugelassene Verdrahtungsabschl sse z B f r einen geschlossenen Regelkreis oder gabelf rmig mit nach oben gerichteten Kabelschuhen zu verwenden...

Page 218: ...etar tanto el aislante como el conductor Varning N r flertr diga ledningar kr vs m ste godk nda ledningskontakter anv ndas t ex kabelsko av sluten eller ppen typ med upp tv nd tapp Storleken p dessa k...

Page 219: ...einen Stromanschlu um Strom g nzlich von der Einheit fernzuhalten m ssen alle Stromzufuhren abgetrennt sein Avvertenza Questa unit ha pi di una connessione per alimentatore elettrico tutte le connessi...

Page 220: ...ung mit TN Stromsystemen ausgelegt Avvertenza Il dispositivo stato progettato per l uso con sistemi di alimentazione TN Advarsel Utstyret er utfomet til bruk med TN str msystemer Aviso O dispositivo f...

Page 221: ...ment Electro Magnetic Compatibility EMC requirements Harmonized Standard covering the essential requirements of the Directive 2014 30 EU EN 55032 2015 CISPR 32 2015 Electromagnetic compatibility of mu...

Page 222: ...RE NEBS Physical Protection Acoustic Noise Maschinenl rminformations Verordnung 3 GPSGV der h chste Schalldruckpegel betr gt 70dB A oder weniger gem ss EN ISO 7779 Translation The emitted sound pressu...

Page 223: ...rmissible to connect the equipment to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the inside wiri...

Page 224: ...ause radio interference in which case the user may be required to take adequate measures Israel Translation from Hebrew Warning This product is Class A In residential environments the product may caus...

Page 225: ...es The QFX Series device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protectio...