Maintaining MX2010 MPCs
Purpose
The router can have up to 10 Modular Port Concentrators (MPCs) mounted vertically in the MPC card
cage at the front of the chassis. For optimum router performance, verify the condition of the MPCs.
Action
On a regular basis:
•
Check the LEDs on the craft interface directly above each MPC slot. The green LED labeled OK lights
steadily when a MPC is functioning normally.
•
Check the OK/FAIL LED on the MPC. For more information, see
MX Series Interface Module Reference
.
If the MPC detects a failure, the MPC sends an alarm message to the Routing Engine.
•
Check the status of installed MPCs by issuing the CLI show chassis fpc command to check the status of
installed MPCs. As shown in the sample output, the value Online in the column labeled State indicates
that the MPC is functioning normally:
user@host>
show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 59 13 0 2048 16 14
1 Online 59 13 0 2048 16 14
2 Online 58 14 0 2048 17 14
3 Online 58 18 0 2048 17 14
4 Online 58 13 0 2048 16 14
5 Online 61 10 0 2048 18 13
6 Online 62 10 0 2048 18 13
7 Online 61 9 0 2048 18 13
8 Online 61 10 0 2048 18 13
9 Online 60 9 0 2048 11 13
For more detailed output, add the detail option. The following example does not specify a slot number,
which is optional:
user@host>
show chassis fpc detail
Slot 0 information:
State Online
Temperature 29
Total CPU DRAM 2048 MB
Total RLDRAM 403 MB
Total DDR DRAM 1572 MB
653
Summary of Contents for MX2010
Page 1: ...MX2010 Universal Routing Platform Hardware Guide Published 2019 12 03...
Page 28: ......
Page 30: ...MX2010 Power System Description 95 MX2010 Cooling System Description 45 4...
Page 144: ...MX2010 DC Power 48 V System Electrical Specifications 201 122...
Page 146: ......
Page 233: ......
Page 273: ...Figure 98 Loading the MX2010 Router into the Rack g007436 256...
Page 294: ...Figure 113 Reinstalling an AC Power Distribution Module g007440 D 277...
Page 295: ...Figure 114 Reinstalling a DC Power Distribution Module 48 V D g007432 278...
Page 373: ...4 PART Installing and Replacing Components Installing Components 359 Replacing Components 429...
Page 374: ......
Page 620: ......
Page 715: ...6 PART Troubleshooting Hardware Troubleshooting Components 703...
Page 716: ......
Page 744: ......
Page 772: ......
Page 775: ...763...
Page 783: ...772...
Page 796: ...Jewelry Removal Warning 787...
Page 799: ...Operating Temperature Warning 790...
Page 808: ...DC Power Disconnection Warning 799...
Page 812: ...DC Power Wiring Sequence Warning 803...