10. Unscrew the nuts counterclockwise using the 13/32 in. (10 mm) nut driver or socket wrench from the
input terminal studs.
11. Remove the cable lugs from the input terminal studs.
How to Install a JNP10K-PWR-DC2 Power Supply
The JNP10K-PWR-DC2 power supply in an MX10016 chassis is a hot-removable and hot-insertable
field-replaceable unit (FRU). You can install up to 10 power supplies in an MX10016 router chassis. All
HVDC power supplies install in the rear of the chassis in the slots along the left side of the chassis.
Before you install an HVDC power supply in the chassis, ensure that you have followed all safety warnings
and cautions:
WARNING:
Before performing DC power procedures, ensure that power is removed
from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel
board that services the DC circuit, router the circuit breaker to the OFF position, and
tape the router handle of the circuit breaker in the OFF position.
WARNING:
Protect yourself from severe burns by wearing heat-protective gloves when
removing a working HVDC power supply from the chassis. HVDC power supplies can
reach 158°F(70°C).
CAUTION:
Before you connect power to the router, a licensed electrician must attach
a cable lug to the grounding and power cables that you supply. A cable with an incorrectly
attached lug can damage the router (for example, by causing a short circuit).
CAUTION:
Do not mix AC, DC, or HVDC power supplies in the same running chassis.
You can mix DC and HVDC power supplies while swapping out one type for another
during installation.
200
Summary of Contents for MX10016
Page 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Page 19: ......
Page 86: ......
Page 123: ......
Page 153: ......
Page 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Page 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Page 241: ......
Page 249: ......
Page 277: ...Restricted Access Warning 281 ...
Page 292: ...Jewelry Removal Warning 296 ...
Page 295: ...Operating Temperature Warning 299 ...
Page 304: ...DC Power Disconnection Warning 308 ...
Page 308: ...DC Power Wiring Sequence Warning 312 ...
Page 311: ...DC Power Wiring Terminations Warning 315 ...
Page 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...