Mirus for H2 Classic GrainGage
36
H2 Classic GrainGage Diagnostics and Alerts
Weight Diagnostics
Item
Description
Weight
Shows the weight of the contents in the weigh bucket . Depending on the
preferred units of measure, weight will be shown in pounds or kilograms .
To change the units of measure see
2.2.2 Set Preferred Units of Measure
page 14 .
Load Cell 1
millivolts / Load
Cell 2 millivolts
These readings are for the two load cells that measure plot weight . The
millivolt readings vary linearly with weight added . The empty weigh bucket
causes the load cells to read between 3 and 4 mV .
Q
This multiplier corrects the weight measurement based on the slope and
motion of the weighing platform .
When Slope and Motion Compensation is disabled, Q is 1 .000 . When slope
and motion compensation is enabled, Q should be 1 .000 +/- .01 (depending
on the slope the combine is on or intensity of vibrations/movement) . If Q
value is off, see
4.1 Slope and Motion Calibration on page 43
.
3.1.4 Moisture Diagnostics
On the Moisture Diagnostics screen, live values are shown
for the moisture sensor in the GrainGage.
Unlock the screen
to view additional
information.
Summary of Contents for HarvestMaster mirus H2
Page 1: ......
Page 7: ...CHAP TER ONE Mirus Ins tallation...
Page 11: ...Mirus and GrainGage S etup CHAP TER T WO...
Page 32: ...H2 Clas sic GrainGage Diagnos tic s and Aler t s CHAP TER THREE...
Page 42: ...GrainGage Calibration CHAP TER FOUR...
Page 71: ...Field Maps CHAP TER FIVE...
Page 98: ...Har ves t Mode CHAP TER SIX...
Page 120: ...Standard Grain Information APPENDIX A...
Page 123: ...Troubleshooting APPENDIX B...
Page 129: ...Limited Warrant y APPENDIX C...