H2 Stationary GrainGage User’s Guide
39
H2 Stationary GrainGage Diagnostics and Alerts
3.1.2 Enter/Exit Glean Mode
Glean Mode is not used with the H2 Stationary GrainGage.
3.1.3 Weight Diagnostics
On the Weight Diagnostics screen, live values are shown
for the load cells.
Weight Diagnostics
Item
Description
Weight
Shows the weight of the contents in the weigh bucket . Depending on the
preferred units of measure, weight will be shown in pounds or kilograms .
To change the units of measure see
2.2.2 Set Preferred Units of Measure
page 21 .
Load Cell 1
millivolts / Load
Cell 2 millivolts
These readings are for the two load cells that measure plot weight . The
millivolt readings vary linearly with weight added . The empty weigh bucket
causes the load cells to read between 3 and 4 mV .
Unlock the
screen to view
additional
information.