
Figure 15: Back-to-Front Airflow Through EX4650 Switch Chassis
g022524
Ports
FRUs
You must install only power supplies that have AIR IN (AFI) labels in switches in which the fan modules
have AIR IN (AFI) labels.
Do Not Mix AIR IN (AFI) and AIR OUT (AFO) Components in the Switch
Do not mix power supplies and fan modules with different airflow labels (AIR IN (AFI) and AIR OUT (AFO))
in the same chassis. If the fan modules have AIR IN (AFI) labels, the power supplies must also have AIR IN
(AFI) labels; if the fan modules have AIR OUT (AFO) labels, the power supplies must also have AIR OUT
(AFO) labels.
The labels on the power supplies and fan modules should match the labels on the switch chassis.
Mixing components with AIR IN (AFI) and AIR OUT (AFO) labels in the same chassis hampers the
performance of the cooling system of the switch and leads to overheating of the chassis.
CAUTION:
The system raises an alarm if a fan module fails or if the ambient temperature
inside the chassis rises above the acceptable range. If the temperature inside the chassis
rises above the threshold temperature, the system shuts down automatically.
38
Summary of Contents for EX4650 Series
Page 1: ...EX4650 Switch Hardware Guide Published 2019 10 10 ...
Page 17: ......
Page 55: ......
Page 78: ......
Page 105: ......
Page 126: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the EX4650 Components 131 ...
Page 127: ......
Page 133: ......
Page 151: ...Restricted Access Warning 155 ...
Page 166: ...Jewelry Removal Warning 170 ...
Page 169: ...Operating Temperature Warning 173 ...
Page 178: ...DC Power Disconnection Warning 182 ...
Page 182: ...DC Power Wiring Sequence Warning 186 ...