4
Charging the battery
WARNING!
The gases produced during charging can cause explosions
The battery produces a mixture of nitrogen and hydrogen (electrolytic gas) during
charging. Gassing is a chemical process. This gas mixture is highly explosive and
must not be ignited.
u
Switch the charging station and truck off first before connecting/disconnecting the
charging cable of the battery charging station to/from the battery connector.
u
The charger must be adapted to the battery in terms of voltage and charge
capacity.
u
Before charging, check all cables and plug connections for visible signs of
damage.
u
Ventilate the room in which the truck is being charged.
u
The battery cover must be open and the battery cell surfaces must be exposed
during charging to ensure adequate ventilation.
u
Do not smoke and avoid naked flames when handling batteries.
u
Wherever an industrial truck is parked for charging there shall be no inflammable
material or lubricants capable of creating sparks within 2 m around the truck.
u
Fire protection equipment must be on hand.
u
Do not lay any metallic objects on battery.
u
It is essential to follow the safety regulations of the battery and charger station
manufacturers.
33
99
29
Safety procedures for charging batteries
Requirements
– Park the truck securely, see page 191.
– Expose the battery, see page 76.
– Switch off the charger.
– Correct charging program set on charger.
78
04.19 en-GB
Summary of Contents for EFX 410
Page 1: ...EFX 410 413 03 13 Operating instructions 51296679 04 19 en GB EFX 410 EFX 413 ...
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 72: ...70 04 19 en GB ...
Page 90: ...88 04 19 en GB ...
Page 250: ...248 04 19 en GB ...
Page 261: ...The Operator specific settings menu now opens 259 04 19 en GB ...
Page 376: ......
Page 380: ...02 16 EN 6 ...
Page 382: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 404: ......