4.9.3
Operation
4.9.3.1
Activating and deactivating the weighing system
Activating the weighing system
Key
Display
– Briefly press the "activate" key.
Z
The weighing system is ready
for use after 5 seconds.
KG/LB
CLR
NET
ID CODE
PT
TOTAL
KG/LB
CLR
e1
e2
e3
STP1
STP2
kg
Deactivating the weighing system
Key
Display
– Press the "deactivate" key for
approx. 3 seconds.
Z
The display switches to OFF.
KG/LB
CLR
NET
ID CODE
PT
TOTAL
KG/LB
CLR
e1
e2
e3
STP1
STP2
4.9.3.2
Checking the zero point
Z
Before each weighing operation, ensure that there is no load on the system and that
it is unoccupied. The weighing system features automatic zero adjustment. This
means that small deviations of the zero point are corrected automatically. If the zero
point is not corrected automatically, a manual adjustment can be performed.
Correcting the zero point
Key
Display
– Briefly press the ">0<" key.
Z
The zero point is corrected.
In the display, the arrow next
to ">0<" indicates that the
zero point has been adjusted.
ID CODE
NET
ID CODE
PT
TOTAL
KG/LB
CLR
e1
e2
e3
STP1
STP2
kg
79
11.19 en-GB