26
D*AP LM 4
Fail Threshold (dBFS)
[-80 … -40]
RMS weighted input level for fail detection.
Fail Wait (s)
[1.5 … 10.0]
elapsed time after fail detection until the switch over will happen.
Fail Return (s)
[0.0 … 10.0]
elapsed time after detection of a proper input signal until the switch
back to the program input.
Side Chain Filter
[OFF / ON]
a high pass filter (300 Hz) and a low pass filter (3000 Hz) is applied
to the detector side chain (not the audio path) to prevent hum and
noise from blocking fail over switching.
Web GUI – AUDIO PROCESSOR – Filter – Spectral Signature
Two options are available to modify the audio signal(s) :
AUDIO PROCESSOR – Filter – Spectral Signature
Link
[Linked / Unlinked]
Spectral Signature
[Enable / Disable]
is a dynamic multi band filter that allows precise control of the audio
spectrum. It is useful in order to create a unique “signature sound” for
audio broadcast.
Note that this feature requires the appropriate license and the additional J*AM Jünger Application Manager
software to be installed separately.
The application manager may be downloaded from the Junger website :
www.junger-audio.com/download/soft-firmware
/
JungerApplicationManager_a.b.cdefg.zip
For details how to operate the J*AM, pls. also see separate manual :
http://www.junger-audio.com/uploads/media/JAM_manual_yymmdd.pdf