Jung UDS 4 REG HE Operating Instructions Manual Download Page 1

Universal dimming station 4-gang 

Light Management  

Universal dimming station 4-gang 

Art.-No.: UDS 4 REG HE

Operating instructions 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Always disconnect before carrying out work on the devise or 
load. At the same time, take into account all circuit breakers that supply dangerous 
voltage to the device or load. 

Danger of electric shock. Device is not suitable for disconnection from supply voltage. 
The load is not electrically isolated from the mains even when the device is switched off. 

Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent 
lamps or LED lamps. Device can be damaged. 

Fire hazard. For operation with inductive transformers, each transformer must be fused 
on the primary side in accordance with the manufacturer's instructions. Only safety 
transformers according to EN 61558-2-6 may be used. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

Figure 1: Device components 

(1)  Load outputs 

A1...A4 

(2)  Keypad for local control 
(3)  Button 

Prog

LED Prog 

(4)  Status LEDs for load outputs 

A1...A4 

(5)  Connection of control sections or control voltage 
(6)  Activation outputs 

A1'...A4'

 / Switching outputs 

E1 ON/OFF...E4 ON/OFF 

(7)  Connection 

Central ON/OFF 

(8)  Connection of hotel card switch 
(9)  Connection for mains supply 

1/17 

82577203 
J:0082577203 

31.05.2011 

Summary of Contents for UDS 4 REG HE

Page 1: ... even when the device is switched off Do not connect any electronic lamps e g switchable or dimmable compact fluorescent lamps or LED lamps Device can be damaged Fire hazard For operation with inductive transformers each transformer must be fused on the primary side in accordance with the manufacturer s instructions Only safety transformers according to EN 61558 2 6 may be used These instructions ...

Page 2: ...mmer station Control outputs A1 A4 for activation of feedback LEDs on the control sections Electronic short circuit protection with permanent switch off after 7 seconds at the latest Electronic over temperature protection Switch on brightness can be adjusted separately for each load output Switch on brightness has been saved permanently Bulb preserving soft start Switch off with dimming function I...

Page 3: ...ated The load outputs are switched off after calibration Function of hotel card switch In combination with a hotel card switch the light is switched on at switch on brightness when the hotel card is inserted When the hotel card is removed any switched on lights remain switched on for 1 minute and the dimmer station can be operated When this time has elapsed the light is darkened within 3 minutes t...

Page 4: ...load output o Operate load output as described above Switching the light on with minimum brightness Local control is switched on and the appropriate load output is selected Light is off o Press the OFF o button for longer than 0 5 seconds Light switches on with minimum brightness The LED OFF o 14 flashes for the length of actuation i Alternatively press the ON n button for longer than 0 5 seconds ...

Page 5: ...e principle One push button control surface or installation button for switch on and brighter and one push button control surface or installation button for switch off and darker The individual load outputs are operated in the same way as for local control It is not possible to save switch on brightnesses with control sections The red Status LED 4 of the operated load output flashes for as long as...

Page 6: ...wer extension A load output is then assigned to the Master of the additional load outputs as a Slave o Connect mains supply 9 as shown in the connection example figure 4 o Connect the hotel card switch as shown in the connection example figure 4 i If no hotel card switch is used then a outer conductor and the neutral conductor must be connected directly All load outputs are switched off Load outpu...

Page 7: ...the Master as a Slave The red status LED 4 of the load output lights up i To delete the assignment press the push button of the Slave again The red status LED 4 goes out o If necessary briefly press the push button of another free load output The load output is assigned to the Master as a Slave The red status LED of the load output lights up o Release the push button of the Master The green Status...

Page 8: ...parallel to the same outer conductor CAUTION When connecting power extensions to load outputs switched in parallel there is no guarantee that the dimmer sets the dimming principle suitable for the load Dimmer power extension and load may be destroyed Do not connect any power extensions to load outputs switched in parallel Only subject load outputs switched in parallel to up to 80 The minimum load ...

Page 9: ... the dimmer station Observe technical data especially the maximum number of sensor modules and push button modules load capacity of the activation outputs and switching inputs o Connect the control section as shown in connection example figure 5 figure 6 or figure 7 Figure 5 Connection example of push button 24 V 4x push button module 24 V 4x Figure 6 Connection example for sensor module or push b...

Page 10: ... or push button module to two dimmer stations according to the connection example figure 8 i Connect the power supply of the dimmer stations to the same outer conductors i Even dimmer stations switched in parallel may only have four sensor modules or push button modules connected to them Operation of multiple dimmer stations with a push button 24 V or push button module 24 V In operation with push...

Page 11: ...e 24 V to two dimmer stations Connection example central function Here Kanal 7 of the push button sensor Central ON and Kanal 8 switches Central OFF Figure 10 Wiring example for Central ON Central OFF o Connect push button sensor 24 V as shown in the wiring example figure 9 or figure 10 i The feedback LEDs of the push button 24 V are only connected to the activation outputs of one dimmer station T...

Page 12: ...e button to switch to the next load output The green and red status LEDs 4 of the next load output flash o Press button Prog 3 briefly The load output is reinitialised The procedure is completed when the green and red Status LED 4 of the load output lights up o Use the push buttons ON n 13 and OFF o 16 to set the minimum brightness o Press button Prog 3 briefly The minimum brightness for the load ...

Page 13: ...tatus LED of output A2 flashes Device address 2 has been set o Press the buttons ON n 13 and OFF o 16 again simultaneously for approx 3 seconds or wait for 15 seconds The dimmer station switches to normal operation The dimmer station has the device address 2 i To set device address 1 again repeat the above steps Switching on status message for sensor modules and push button modules In operation wi...

Page 14: ...ule i If cloning mode is activated on the dimmer station when there are no sensor modules or push button modules connected cloning mode will be terminated automatically after 3 minutes 6 Appendix 6 1 Technical data Rated voltage AC 230 V Mains frequency 50 60 Hz Power loss max 20 W Standby power max 2 W Terminals Control voltage DC 24 V SELV Current carrying capacity Σ 80 mA Total length of contro...

Page 15: ... tripped the red and green Status LEDs 4 of the appropriate load output flash Eliminate short circuit Switch on load output again i Short circuit protection is not based on a conventional fuse no metallic separation of the operational current Cause 2 overtemperature protection has tripped the red Status LED 4 of the appropriate load output flashes Load output is defective Load output switches the ...

Page 16: ...ntral controller Cause no central controller is assigned to the load output Assign central controller see Commissioning Load output does not switch on using the hotel card switch Cause no central controller is assigned to the load output Assign central controller see Commissioning 6 3 Accessories Relay station universal 8 gang Art No RS 8 REG HE Sensor module 8 gang Art No SM 1608 Push button modu...

Page 17: ...80 61 89 mail vka jung de General equipment Service Line 49 0 23 55 80 65 55 Telefax 49 0 23 55 80 62 55 mail vkm jung de KNX equipment Service Line 49 0 23 55 80 65 56 Telefax 49 0 23 55 80 62 55 mail vkm jung de The Œ symbol is a free trade symbol which is solely intended for the authorities and does not guarantee any properties ALBRECHT JUNG GMBH CO KG Volmestraße 1 D 58579 Schalksmühle Telefon...

Reviews: