6. Battery signals
6.1 Charging status indication (LED blue)
The blinking patterns are shown in the following figure.
Charger disconnected
no blinks
Pre-heating stage
1 blink
Pre-charging stage
2 blinks
Main charging stage
3 blinks
Balancing stage
4 blinks
Charging finished
slow blink
Charging error
rapid blink
6.2 Buzzer signal tone (LED yellow)
Pulse patterns are regiven as following fugure:
"Low Cell Voltage" reduction is active
Charging error occurred
1 s
constant LOW
750 ms
750 ms
200 ms
750 ms
200 ms
750 ms
200 ms
750 ms
200 ms
50 ms
250 ms
250 ms
350 ms
150 ms