The range of the system can be optimised by selecting the optimal installation location, taking
into account the structural circumstances.
Figure 2: Reduced range due to structural obstacles
Example of penetration of various materials:
Material
Penetration
Wood, Plaster, Plasterboard
approx. 90%
Brick, Chipboard
approx. 70%
Reinforced concrete
approx. 30%
Metal, Metal grid
approx. 10%
Rain, Snow
approx. 1-40%
Intended use
-
Radio-controlled switching and brightness setting for lamp operating devices with 1-10 V
interface
-
Installation in false ceilings or surface mounting
-
Operation with suitable radio transmitters
i
It is not possible to teach a combination of presence detector and motion detector.
Product characteristics
-
Switch-on brightness can be saved permanently
-
Switch-on via bulb-preserving soft start
-
Light scene operation possible
-
Constant light regulation possible in connection with a radio presence detector
-
Run-on time of approx. 1 minute in connection with radio motion detectors
4 Operation
A radio transmitter has to be taught in order to be able to operate the device.
i
Observe the instructions for the radio transmitter.
2/5
32532333
J0032532333
08.09.2016
Radio Management
Radio push-button controller, built-in