8.8 Error at gateway reset
4
There is no long acoustic signal at
network reset.
Remedy:
(1)
Reconnect power cable.
(2)
If necessary repeat gateway reset
several times.
Ensure that you maintain the
pressure point of the gateway
button (B).
Smoke alarm device incorrectly
positioned
•
Excessive or insufficient distance
between smoke alarm devices
Remedy:
(1)
Return all of the smoke alarm devic-
es to the default state and reset the
radio module on the gateway
(see chapter 5.1 “Gateway reset” on
page 25, step 2).
(2)
Mount smoke alarm devices with
the prescribed relative distance.
(3)
Reconnect gateway
(see chapter 4.7 “Connecting the
gateway” on page 18).
(4)
Set up radio group again
(see chapter 4.8 “Setting up the
radio group and integrating the
gateway” on page 19).
(5)
After finishing the new installation,
perform a network scan
(see chapter 4.9 “Network scan” on
page 21).