Jung FP 701 CT Operating Instructions Manual Download Page 3

 

KNX Facility-Panel 

Ref.-no.: FP 701 CT 

 

 

(3) Screen page 

(4) Control or display element 

(5) Scroll bar 

(6) Function keys 

Touch sensitive surface 

The display screen features a touch-sensitive surface, the so-called touch 
screen. The device is operated by touching the screen surface with the 
finger or by special touch screen pens (not included). 

L

  Do not use sharp objects. The surface could be damaged affecting 

the operation of the device. 

Status line 

If programmed, the status line (2) will be visible at the upper screen edge. 
The status line displays up to ten elements: 

 Event 

display 

 

Centralized fault message 

 Value 

display 

 

Date, time of day 

Screen page 

Control and display elements (4) or images are displayed on screen 
pages (3). Control and display elements (4) indicate states, take you to 
other pages or symbolize devices, functions to be controlled and 
components, e.g. lighting fixtures, blinds, heating devices and air 
conditioners etc.. 

Scroll bar 

The scroll bar (5) is used to navigate through one or several pages. 
Pressing the arrow keys will let you switch between the key elements. 

 

Double arrow keys: visible only, if connected pages are available. 
The display will switch to a connected page. 

 

Arrow keys: Switching between the display elements of the current 
page. 

Function keys 

There is a maximum of four function keys (6) available for each control 
element (4) which can be displayed and operated after selecting the 
control element. 

Selecting functions / consumers 

In order to use a function, it has to be selected first. 

 

Activate the page with the element that represents the function to 
be displayed or controlled. 

 

Select the desired element with the finger. 

The screen switches the display. 

- or 

the appropriate function keys will be displayed. The function can be 
operated. 

 

Summary of Contents for FP 701 CT

Page 1: ...structions may cause damage to the device and result in fire and other hazards These instructions are part of the product and must be left with the customer 2 Technical overview 1 Touch Screen surface...

Page 2: ...on the display Fitting position horizontal or vertical USB port for fast programming Max of 1600 operating functions 400 display functions Max of 50 pages Max of 24 light scenes with 32 actuator grou...

Page 3: ...her pages or symbolize devices functions to be controlled and components e g lighting fixtures blinds heating devices and air conditioners etc Scroll bar The scroll bar 5 is used to navigate through o...

Page 4: ...ed in the device during programming Select timer page Select the desired timer function and press Change The switching times for the selected timer function will be displayed Select the switching time...

Page 5: ...ept the settings Press Cancel back Quit the Light scenes page Press Back L It is also possible to save a scene by first adjusting the scene manually After that highlight the desired scene on the Light...

Page 6: ...screen surface will cause no action Open the Service page Activate Cleaning function The touch will not be evaluated for the duration of 1 minute The device displays the remaining cleaning time on the...

Page 7: ...lt messages Viewing the service address Open the Service page Open System settings Select Service address The pre set maintenance will be displayed Changing the colour settings The colour setting is v...

Page 8: ...passwords Select the desired password level Enter the new password Accept the entry by pressing Save Viewing the past events The device saves important events in the past events memory such as reset...

Page 9: ...terminal for future upgrades e g external pushbutton 12 Reset key 13 Reset LED 14 USB Terminal Installation in flush mounting box figure 4 17 L Programming key and LED are accessible only from the bo...

Page 10: ...t pushbuttons Pay attention to correct assignment Connect pushbutton cable to Ext terminal 11 Pin assignment figure 5 Pin Nr Bild 5 Funktion 1 GND 2 Key 1 arrow up 3 Key 2 arrow down 4 Key 3 function...

Page 11: ...drivers are certified The corresponding messages can be ignored and the installation continued L Connect only one device to the PC After installation of the device Remove design frame 16 from the devi...

Page 12: ...r guarantee within the scope of the statutory provisions Please return the unit postage paid to our central service department giving a brief description of the fault ALBRECHT JUNG GMBH CO KG Service...

Reviews: