6 Appendix
6.1 Technical data
Rated voltage
AC 230 V ~
Mains frequency
50 / 60 Hz
Ambient temperature
-5 ... +45 °C
Switching current for AC 230 V ~
Ohmic
16 A
For switching current >10A connecting cable 2.5mm²
Fluorescent lamps
4 AX
Minimum switching current AC
100 mA
Contact type
µ
Standby power
max. 0.2 W
Connected load
Incandescent lamps
2300 W
HV halogen lamps
2000 W
Tronic transformers
1500 W
HV-LED lamps
typical 500 W
Compact fl lamp.
typical 500 W
Inductive transformers
1000 VA
Fluorescent lamps, uncompensated
920 VA
Capacitive load
690 VA (560 µF)
Connection of load terminals
single stranded
1.5 ... 4 mm²
finely stranded without conductor sleeve
0.75 ... 4 mm²
Finely stranded with conductor sleeve
0.5 ... 2.5 mm²
Fitting width
36 mm / 2 modules
Bus line
Rated voltage
DC 12 V SELV
Current consumption
max. 20 mA
Connection, Bus
Connection terminal
Cable length
max. 3 m
6.2 Parameter list
Settings window
Device settings
Parameters
Setting options, Basic
setting
Explanations
Manual commissioning
On, Off
Basic setting: On
Blocks manual commissioning
for all device channels. In the
"Off" setting, the device
cannot be reset to the factory
setting.
Settings, channel
Parameters
Setting options, Basic
setting
Explanations
Manual commissioning
On, Off
Basic setting: On
Blocks manual commissioning
for the device channel. In the
"Off" setting, the device
cannot be reset to the factory
setting.
6/11
82581713
J:0082581713
11.03.2014
eNet
Radio switch actuator for rail mounting, 1-channel