5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before working on the device, disconnect the power supply and cover up live
parts in the working environment.
Fitting the device
o
Mount device on DIN rail. Output terminals must be at the top.
Connect bus line
Figure 2: Connection diagram of bus line
Labelling / Colour
Connection
DC–
/
GY
dark grey
Power supply –
DC+
/
RD
red
Power
Bus–
/
WH
white
Data cable –
Bus+
/
YE
yellow
Data cable +
As bus line, use e.g. J-Y(St)Y 2x2x0.8
o
Connect the device with bus line (figure 2) to the RMD reception module and power supply
(see instructions of RMD reception module and power supply).
3/11
82581713
J:0082581713
11.03.2014
eNet