You can find further information about the eNet system on our website.
The device may be operated in all EU and EFTA countries.

Intended use

-

Switching of lighting

-

Operation with suitable eNet radio transmitters

-

Operation with power supply RMD and receiver module RMD cover or eNet server (see
accessories)

-

Installation in distribution boxes on DIN rail according to EN 60715

Product characteristics

-

Operating mode switch for switch/push-button actuator switch-over or parameterisation via
eNet server

-

Status feedback to radio transmitter

-

Scene operation possible

-

Switchable output with 

Prog

 button

-

Status indicator via LED

Switching mode of operation:
-

Switch-on telegram: Device switches on

-

Switch-off telegram: Device switches off

Operating mode buttons:
-

Relay contact remains closed as long as ON or OFF telegrams are being received

-

The maximum switch-on time is 60 seconds

Can be set with eNet server:
-

Flash function

-

Run-on time

-

Switch-on delay / switch-off delay

-

Operation as NO or NC contacts

-

Switch-off warning

-

Minimum switching repeat time

-

Operation locks

-

Continuous on, Continuous off

i

If settings are changed with the eNet server, operation and signalling could vary from what
is described here.

i

The parameter list is in the Internet in the documentation for this device.

Supplementary functions with eNet server:
-

Update of the device software

-

Reading of error memory

Behaviour in case of bus voltage failure and return

If the bus voltage fails, the actuator switches off. The response to bus voltage return can be
parameterised with eNet server. Default setting: Off.

4 Operation

Operation is with radio transmitters, please observe the radio transmitter instructions.

Operation with Prog button

o

Press 

Prog

 button briefly.

The load switches on or off.
Status-LED lights up: output is switched on.
Status-LED  off: output is switched off.

2/11

82581713
J:0082581713

11.03.2014

eNet

Radio switch actuator for rail mounting, 1-channel

Summary of Contents for eNet FM AS 16 REG

Page 1: ...ns and standards which apply for SELV circuits Danger of electric shock Device is not suitable for disconnection from supply voltage Fire hazard Operation exclusively with the power supplies listed un...

Page 2: ...0 seconds Can be set with eNet server Flash function Run on time Switch on delay switch off delay Operation as NO or NC contacts Switch off warning Minimum switching repeat time Operation locks Contin...

Page 3: ...on DIN rail Output terminals must be at the top Connect bus line Figure 2 Connection diagram of bus line Labelling Colour Connection DC GY dark grey Power supply DC RD red Power supply Bus WH white Da...

Page 4: ...eter set with eNet server M Operating mode buttons K Switching mode of operation If the operating mode switch is turned from the position PC to another operating mode the parameters are set to the def...

Page 5: ...place i Scene buttons must be connected separately Disconnecting connection to a radio transmitter o Carry out the same steps as when connecting see Connecting actuator to radio transmitters The statu...

Page 6: ...ctor sleeve 0 75 4 mm Finely stranded with conductor sleeve 0 5 2 5 mm Fitting width 36 mm 2 modules Bus line Rated voltage DC 12 V SELV Current consumption max 20 mA Connection Bus Connection termina...

Page 7: ...rameter Switch off delay is used for the pulse time and the parameter Switch on delay for the pause time Continuous on The output switches to continuously On All operations of radio transmitters and t...

Page 8: ...e set time apply to operation using radio transmitters The relay is switched immediately when the Prog button is pressed Run on time 0 s 24 h Basic setting 0 s As soon as a run on time has been entere...

Page 9: ...nnel Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Priority wind alarm 0 4 Basic setting 3 Specifies the prio...

Page 10: ...ching repeat time starts after each switching operation Operating hours 0 65535 Basic setting Current value The time is counted during which the load is physically switched on relay contact closed Thi...

Page 11: ...of technical progress We provide a warranty as provided for by law Please send the unit postage free with a description of the defect to our central customer service office ALBRECHT JUNG GMBH CO KG V...

Reviews: