1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Always disconnect before carrying out work on the devise or 
load. At the same time, take into account all circuit breakers that supply dangerous 
voltage to the device or load. 

Danger of electric shock. Device is not suitable for disconnection from supply voltage. 
The load is not electrically isolated from the mains even when the device is switched off. 

Do not press on the sensor window. Device can be damaged. 

Disconnect before mounting the cover, malfunction possible. 

Keep button cells out of reach of children! If button cells are swallowed, get medical help 
immediately. 

Risk of explosion! Do not throw batteries into fire. 

Risk of explosion! Do not recharge batteries. 

The device is not suitable for use as a burglar alarm or other alarm. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

Figure 1 

(1)  Insert 
(2)  Frame 
(3)  Motion detector 
(4)  LED red 
(5)  Button Off/Auto 
(6)  LED yellow 

1/13 

32576803 
J:0082576803 

03.05.2011 

Summary of Contents for AS 1280-1 Series

Page 1: ...Device is not suitable for disconnection from supply voltage The load is not electrically isolated from the mains even when the device is switched off Do not press on the sensor window Device can be...

Page 2: ...imit is reached To avoid any light swings caused by a cooling illuminant the motion detector does not evaluate any motion signals for a brief lockout time after switching off The motion detector adjus...

Page 3: ...he light is switched on for the run on time after mains return Longer than 2 seconds The motion detector goes through a self test for approx 40 seconds after mains return The light is first switched o...

Page 4: ...er than 10 seconds Adjusting detection angle Brightness threshold approx 1 lux night operation Brightness threshold approx 10 lux switching takes place during twilight Brightness threshold 150 lux set...

Page 5: ...switched on output HLK continues switching motion dependent Switching off On for 2 hours or Continuous on o Press button for Continuous on function press alternative button 7 on the motion detector A...

Page 6: ...tton or 2 wire extension insert over entire surface for longer than 3 seconds Switch on brightness is saved For confirmation the light is switched off briefly and switched on again i In the state as s...

Page 7: ...an 10 seconds i No run on time is set in short time operation i With the HVAC insert the function is only executed for Kanal 1 output i To switch off short time operation press Reset button for less t...

Page 8: ...e extension insert Only a few settings are possible in combination with a 3 wire extension insert Setting sensitivity see Chapter Operation on a main unit Use outdoors see Chapter Operation on a main...

Page 9: ...o Avoid interference sources in the detection area Interference sources such as heaters fans air conditioners and cooling illuminants can lead to unwanted switching Motions crosswise to the motion det...

Page 10: ...with the frame onto the concealed insert i Do not connect any main units in parallel This can lead to light swings 6 2 Commissioning Insert battery into IR remote control i Keep contacts of batteries...

Page 11: ...s Installation height 1 10 2 20 m Detection angle 180 cross walking range approx 12 x 6 m walk to walking range approx 8 4 m Short time operation pulse duration approx 0 3 s pulse stop approx 2 7 s I...

Page 12: ...ity Limit detection area Cause 2 On for 2 hours or Continuous on is activated Switch on automatic mode Cause 3 Night light function is switched on The light stays on at 20 brightness Switch off night...

Page 13: ...61 89 mail vka jung de General equipment Service Line 49 0 23 55 80 65 55 Telefax 49 0 23 55 80 62 55 mail vkm jung de KNX equipment Service Line 49 0 23 55 80 65 56 Telefax 49 0 23 55 80 62 55 mail...

Reviews: