ƾ
Cooling icon lights up: cooling mode, no cooling is taking place
Cooling icon flashes: cooling mode, cooling is taking place
ƿ
Heating icon lights up: heating mode, no heating is taking place
Heating icon flashes: heating mode, heating is taking place
Icons of the operating area (4)
Ƨ
Step back / display current time
ƨ
Confirm input / display current time
Ƙ
Switch between manual operation and automatic operation
+ / –
Increase or reduce the displayed temperatures or times / navigation in
menu
ƣ
Call up and terminate the programming menu
3
Intended use
–
Manual and time-controlled regulation of the room temperature
–
Operation with Room thermostat insert or system insert for switching
4
Product characteristics
–
Timer with three memory areas
Comfort and ECO time for Mo-Fr and Sa-Su in each memory area
–
Setting a comfort, ECO, cooling and frost protection temperature
–
Current time can be saved as switching time, quick programming
–
Automatic summer time changeover, can be switched off
–
Illuminated segment display for easy reading
–
Operating lock
–
Optimised heating up (temperature is reached at the set time), can be
switched off
–
Adaptation to valves (deenergised open or deenergised closed)
–
Cooling mode possible
–
Supports internal and external temperature sensor
–
Temperature drop detection (call-up of frost protection temperature when win-
dow is opened)
–
Offset adjustment (correction value for measured temperature)
–
Controller output working method: pulse width modulation (PWM) or two-point
–
Valve protection function (once a week opening and closing of valve, on Sat-
urdays at 11 a.m.)
–
Interrupts the heating process after 60 minutes for 5 minutes
–
Display switch-off after 2 minutes or permanent indication available
LB Management room thermostat display
4 / 14
32401513
17.08.2022
J0082401513