DESCRIPTION

This manual applies to a Jung Pumpen 

pre-fabricated Hebefix tank, which can 

be equipped with a U 3 KS or U 3 KS 

spezial.

ATTENTION!

 The Hebefix is designed 

for usual domestic drainage water, ac-

cording to DIN 1986, part 3. In some 

countries it must not be used for pump-

ing sewage water from lavatories, for 

further informations ask your distribu-

tor.
The allowed temperature of the pumped 

medium is 35° C (short time period 60° 

C).
Disposal of condensate from condens-

ing boilers with the pump U 3 KS spezial 

only.
The Hebefix has 4 marked connec-

tion branches for tubes with diameter 

40 mm / 50 mm, to connect a sink, a 

washing machine, a dish washer, and in 

connection with a special float a shower 

can be connected as well. 
Der Hebefix sollte mit den Entwässe-

rungsgegenständen im selben Raum 

installiert sein. By using the lower in-

lets, a special float (JP44795) should be 

used to allow a free flow of inlet pipe is 

guaranteed. The hose connection is in-

tended for use on the upper inlets.
The pressure tube can be installed right 

or left handed through the upper con-

nection pieces of the tank casing.
Ventilation:
Sumps and tanks for the drainage of a 

cellar should be covered and, if neces-

sary, specially ventilated (EN 12056-4).
Ventilations with additional activated 

carbon filters decrease annoyance 

caused by bad smell.
The tank has 2 suspension eyes, to 

mount it on the wall if necessary, to 

make floor cleaning easier.

Scope of delivery

Above floor tank Hebefix with circular 

sealing, rubber feet and activated car-

bon filter. 
Bag with swing-type check valve 1 ¼“, 5 

plug seals, hose connection d=25, bend 

d=40 mm, 2 hose clamps, sealing plug 

for tank ventilation (d=12,3 mm), fasten-

ing material, manual and drilling tem-

plate.

Dimensions

ELECTRICAL 

CONNECTION

Please refer to the relevant instructions 

in the manual for the pump.

INSTALLATION

The Hebefix is installed according to the 

examples. According to EN 12056-4 the 

pressure tube must be taken in a loop 

over the local backpressure level and 

secured with a reflux valve. The reflux 

valve 1 1/4" is in the extent of delivery.
Each drain connection (e.g. washing 

machine, dish washer ...) must have a 

siphon trap. 

Mounting

1. Remove the tank cover (loosen the 

snap connections on the narrow sides, 

but do not overstretch). Withdraw the 

accessories. Screw the pump elbow 1 

¼“ with sealing tape or a hemp packing 

on the pump discharge. Behälterdeckel 

abnehmen (Schnappverbindung an den 

Schmalseiten lösen, aber nicht über-

dehnen). 
Do not install the internal pump reflux 

valve. Push the elastic outlet elbow on 

the connection branch of the pump, ad-

just it and tighten it with the hose clamp.
2. Open required connection piece for 

pressure, inlet (and ventilation) at the 

marked position, by cutting or drill-

ing (Ø 46 resp. Ø 58). 

ATTENTION

: Do 

not damage the faying surface! Push 

the plug-in seals into the opened con-

nection branches. If necessary, push 

the hose connection d=25 with an o-

ring seal 40x3 into a lateral connection 

piece. 

3. Put the pump with the outlet elbow 

into the floor lock of the tank. Push the 

pressure tube from outside through to 

the plug-in seal into the elastic out-

let elbow and fix it with a hose clamp. 

Push the inlet and ventilation pipe about 

35 mm into the plug-in seal.

Summary of Contents for Hebefix

Page 1: ...B 26155 4 1 1401 www jung pumpen de JUNG PUMPEN HEBEFIX 3 DE Original Betriebsanleitung EN Instruction Manual FR Instructions de service NL Gebruikshandleiding IT Istruzioni per l uso ...

Page 2: ...2 ...

Page 3: ...sind zu beachten Sicherheitshinweise für den Betrei ber Bediener Gesetzliche Bestimmungen lokale Vor schriften und Sicherheitsbestimmun gen müssen eingehalten werden Gefährdungen durch elektrische Ener gie sind auszuschließen Leckagen gefährlicher Fördergüter z B explosiv giftig heiß müssen so abgeführt werden dass keine Gefähr dung für Personen und die Umwelt ent steht Gesetzliche Bestimmungen si...

Page 4: ...e Bodenreinigung im Aufstellbereich ermöglichen Lieferumfang Überflurbehälter Hebefix mit Überlauf ventil Profilschnurring Gummifüßen und Aktivkohlefilter Beutel mit Rückschlagklappe 1 5 Steck dichtungen Schlauchan schluss d 25 Abgangskrümmer Muffe d 40mm 2 Schlauchschellen Ver schlussstopfen für Behälterlüftung d 12 3mm 2 Hakenschrauben 2 Holzschrauben 4 Dübel S6 2 Kappen für Kappenschrauben Betr...

Page 5: ...befix z B unter dem Waschbecken an die Wand gehängt dann können mit der beigelegten Bohr schablone die Löcher für diese Befesti gung angezeichnet werden In die obe ren Löcher werden die Hakenschrauben eingedreht und in die unteren Löcher werden je zwei Gummifüße des Behäl ters als elastische Abstandshalter be festigt Bodenfreiheit für den Behälter ca 80 bis 100 mm wählen Zubehör Sonderschwimmer De...

Page 6: ...al working operating and safety regulations must be adhered to Safety instructions for the operator user All legal regulations local directives and safety regulations must be adhered to The possibility of danger due to electri cal energy must be prevented Leakages of dangerous e g explosive toxic hot substances must be dis charged such that no danger to people or the environment occurs Legal regu ...

Page 7: ...nd activated car bon filter Bag with swing type check valve 1 5 plug seals hose connection d 25 bend d 40mm 2 hose clamps sealing plug for tank ventilation d 12 3mm fasten ing material manual and drilling tem plate Dimensions ELECTRICAL CONNECTION Please refer to the relevant instructions in the manual for the pump INSTALLATION The Hebefix is installed according to the examples According to EN 120...

Page 8: ...ws into the upper holes and fix two rubber bases in the lower holes as elastic distance pieces The distance between bottom and floor should be ap prox 80 to 100 mm Accessory Special float At connecting a shower basin the pump can only be operated with the special float JP44795 ATTENTION If the inlet in the cover is also used an elbow must be fixed on the inlet pipe to prevent the access of air in ...

Page 9: ...ple doivent être évacuées de telle sorte qu elles ne représentent au cun danger pour les personnes et l en vironnement Les directives légales en vigueur sont à respecter Consignes de sécurité pour le mon tage les travaux d inspection et de maintenance D une manière générale les travaux à effectuer devront l être exclusivement sur une machine à l arrêt Les pompes ou agrégats refoulant des matières ...

Page 10: ...s encastrables raccord de tuyau d 25 coude de sortie manchon d 40mm 2 colliers bouchon d obtu ration pour ventilation du collecteur d 12 3mm 2 vis à crochets 2 vis à bois 4 chevilles S6 2 embouts pour vis à embouts Instructions d utilisation et gabarit de perçage Dimensions principales INSTALLATION ÉLECTRIQUE Veillez respecter en outre les consignes correspondantes dans les instructions d utilisat...

Page 11: ...efix est par exemple suspendue au mur sous le lavabo les trous pour cette fixation peuvent être tracés à l aide du gabarit de perçage fourni Les vis à crochets sont vissées dans les trous supérieurs et dans les trous inférieurs deux pieds en caoutchoucs de la cuve sont fixés en guise d entretoises élastiques Choi sir une garde au sol pour le collecteur d environ 80 à 100 mm Accessoire Flotteur spé...

Page 12: ...enaar Er moet worden voldaan aan wettelijke ei sen lokale regelgeving en veiligheidseisen Risico s door elektrische energie moeten worden uitgesloten Gemorste gevaarlijke afvoerproducten bijv explosief giftig heet moet zodanig worden verwijderd dat er geen gevaar optreedt voor mens en milieu De wettelijke bepalingen moeten in acht worden genomen Veiligheidsinstructies voor montage in spectie en on...

Page 13: ...door een eenvoudige bodemreini ging in het opstellingsbereik mogelijk maken Leveromvang Bovenvloers reservoir Hebefix met overloopventiel profielsnoerring gum mi voetjes en actiefkoolfilter Buidel met Terugslagklep 1 5 in steekdichtingen slangaansluitingd 25 afvoerbocht mof d 40mm 2 slang klemmen afsluitstoppen voor reser voirventilatie d 12 3mm 2 haak schroeven 2 houtschroeven 4 tappen S6 2 kappe...

Page 14: ...bekken aan de wand gehangen kunnen met de meegeleverde boorsjablonen de gaten voor deze bevestiging aangeduid worden In de bovenste gaten worden de haakschroeven ingedraaid en in de onderste gaten worden telkens twee gummi voetjes van het reservoir als elastische afstandshouders bevestigd Bodemvrijheid voor het reservoir ca 80 tot 100 mm kiezen Accessoires speciale vlotter De speciale vlotter JP44...

Page 15: ...stite in modo che non costituiscano un pericolo per le persone o per l ambiente Osservare le norme in vigore Indicazioni di sicurezza per le opera zioni di montaggio ispezione e manu tenzione In linea di principio si devono eseguire operazioni solo a macchina spenta Le pompe o i gruppi che pompano sostan ze pericolose per la salute devono es sere decontaminati Subito dopo il termine delle operazio...

Page 16: ...1 curva di uscita manicotto d 40mm 2 graffette stringitubo 1 tappo di chiu sura per la ventilazione del contenitore d 12 3mm 2 ganci a vite 2 viti per legno 4 tasselli S6 2 tappi per viti a ca lotta Manuale di istruzioni per l uso con l e lenco delle parti di ricambio 1 dima di foratura Disegno quotato ALLACCIAMENTO ELETTRICO Tenere presenti le avvertenze indicate nel manuale di istruzioni della U...

Page 17: ...ti le due calotte di colore bianco fornite in dotazione A questo punto il contenitore Hebefix è pronto all uso 7 Se il contenitore Hebefix viene mon tato sospeso a parete ad es sotto al lavabo è possibile tracciare i fori di fis saggio con la dima di foratura fornita in dotazione Avvitare i ganci a vite nei fori in alto e in ciascuno dei fori in basso fis sare due piedi in gomma del contenito re c...

Page 18: ...estr 4 6 33803 Steinhagen Deutschland Tel 49 5204 170 Fax 49 5204 80368 eMail kd jung pumpen de PENTAIR WATER ITALY Srl Via Masaccio 13 56010 Lugnano Pisa Italia Tel 39 050 71 61 11 Fax 39 050 70 31 37 eMail info jung pumpen it ...

Reviews: