Remote mount design (transmitter)
(1)
Type
406018
JUMO flowTRANS MAG 01 – transmitter
(2)
Design
2
Remote mount
a, b
(3)
Explosion protection
0
Without Ex-protection
1
With Ex-protection
(4)
Ambient temperature for sensor
X X
1
Standard transducer design/-20 to +60 °C (-4 to +140 °F)
(5)
Nameplate
X X
1
Adhesive label
X X
2
Stainless steel
X X
9
Others upon request
(6)
Signal cable length
c
X X
0
None
(7)
Ex-zone
X
0
None
X
1
ATEX/IECEx zone 1
d
X
2
ATEX/IECEx zone 2/21
(8)
Protection type for transmitter
X X
1
IP67 (NEMA 4X)
e
(9)
Cable fitting
X X
1
M20 × 1.5
X X
2
1/2
″
NPT
(10)
Voltage supply
X X
1
AC 100 to 230 V, 50 Hz
X X
2
AC/DC 24 V, 50 Hz
(11)
Signal inputs and outputs
X X
1
HART and 20 mA passive and pulse and contact input/output
f
X X
2
HART and 20 mA active and pulse and contact input/output
g
X
3
HART and 20 mA active and pulse and contact output
h
X X
4
PROFIBUS-PA and contact output
(12)
Default settings/diagnosis
i
X X
0
None/standard diagnostics functions
X X
1
Parameters: default settings; standard diagnosis activated
a
If the sensor model 406012/2-0 or 406012/2-1 is also required for the transmitter model 406018/2-0 or 406018/2-1, the order code „Compact
or remote mount design (sensor with transmitter) “, page 47 should be used to generate the correct order details.
b
If only the sensor model 406012/2-0 or 406012/2-1 is needed, the order code „Remote mount design (sensor) “, page 51 should be used to
generate the correct order details.
c
For the model 406018/2-1 in the version for Ex-zone 1, 10 m (32.81 ft) cables are permanently connected to the transmitter. For maximum signal
cable lengths
see „Signal cable length and preamplifier “, page 11
d
Only in conjunction with dual-compartment housing.
e
Protection type for transmitter = IP67 (NEMA 4X) for single and dual-compartment housing.
f
Available for version Ex-zone 2 or Ex-zone 1 or without Ex-protection.
g
Available for version Ex-zone 2 or without Ex-protection.
h
Available for version Ex-zone 1.
i
If the transmitter (model 406018/2-0, 406018/2-1) is ordered as a spare part or without sensor, "None/standard diagnostics functions" should
be selected.