![JUMO flowTRANS MAG H01 Operating Manual Download Page 185](http://html1.mh-extra.com/html/jumo/flowtrans-mag-h01/flowtrans-mag-h01_operating-manual_2031178185.webp)
185
13 Technical data
13.2.6
Protection type according to EN 60529
13.2.7
Pipe vibration according to EN 60068-2-6
Valid for:
Remote mount design
Lining
Flange
Ambient temperature
Medium temperature
material
Minimum
Maximum
Minimum
Maximum
Hard rubber
Steel
-10 °C (14 °F)
60 °C (140 °F)
-10 °C (14 °F)
80 °C (176 °F)
a
a
For version "Sensor housing made of steel"
90 °C (194 °F)
Stainless steel -15 °C (5 °F)
60 °C (140 °F)
-15 °C (5 °F)
80 °C (176 °F)
a
90 °C (194 °F)
Soft rubber
Steel
-10 °C (14 °F)
60 °C (140 °F)
-10 °C (14 °F)
60 °C (140 °F)
Stainless steel -15 °C (5 °F)
60 °C (140 °F)
-15 °C (5 °F)
60 °C (140 °F)
PFA
PTFE
Thick PTFE
ETFE
b
b
For version "Sensor housing made of aluminum (double shell housing)"
Steel
-10 °C (14 °F)
60 °C (140 °F)
-10 °C (14 °F)
130 °C
(266 °F)
Stainless steel
-25 °C (-13 °F)
-40 °C (-40 °F)
c
c
for low temperature version (optional)
60 °C (140 °F)
45 °C (113 °F)
-25 °C (-13 °F)
130 °C
(266 °F)
Ceramic
Carbide
Steel
-10 °C (14 °F)
60 °C (140 °F)
-10 °C (14 °F)
80 °C (176 °F)
Stainless steel
-20 °C (-4 °F)
60 °C (140 °F)
-20 °C (-4 °F)
80 °C (176 °F)
Remote mount design (high-temperature version)
a
a
For version "Sensor housing made of aluminum (double shell housing)"
Lining
Flange
Ambient temperature
Medium temperature
material
Minimum
Maximum
Minimum
Maximum
PFA
Thick PTFE
Steel
-10 °C (14 °F)
60 °C (140 °F)
-10 °C (14 °F)
180 °C (356 °F)
Stainless steel
-25 °C (-13 °F)
60 °C (140 °F)
-25 °C (-13 °F) 180 °C (356 °F)
-40 °C (-40 °F)
b
b
for low temperature version (optional)
ETFE
a
Steel
-10 °C (14 °F)
60 °C (140 °F)
-10 °C (14 °F)
130 °C
(266 °F)
130 °C
(266 °F)
Stainless steel
-25 °C (-13 °F)
60 °C (140 °F)
-25 °C (-13 °F)
-40 °C (-40 °F)
b
Compact design (internal transmitter)
IP65, IP67 (NEMA X4)
Remote mount design (external transmitter)
IP65, IP67 (NEMA X4), IP68
Compact design
(With aluminum transmitter housing)
In the range 10 to 58 Hz
max. 0.15 mm (0.006") deflection
In the range 58 to 150 Hz
max. 2 g acceleration
Remote mount design
(Sensor)
In the range 10 to 58 Hz
max. 0.15 mm (0.006") deflection
In the range 58 to 150 Hz
max. 2 g acceleration
Summary of Contents for flowTRANS MAG H01
Page 2: ......
Page 22: ...1 Safety 22...
Page 68: ...5 Electrical connection 68...
Page 72: ...6 Digital communication 72...
Page 94: ...7 Startup 94...
Page 108: ...8 Parameterization 108...
Page 109: ...109 8 Parameterization...
Page 110: ...8 Parameterization 110...
Page 111: ...111 8 Parameterization...
Page 112: ...8 Parameterization 112...
Page 152: ...8 Parameterization 152...
Page 160: ...9 Advanced diagnostics functions 160...
Page 258: ...14 Annex 258...