11 Data overview

54

11.5

Calibration data

Data point

Explanation

Rel. cell constant

The deviation from the nominal cell constant is described by the relative cell 
constant. It is established by the calibration.

Remaining running time on calibra-
tion timer

Elapsed time on calibration timer
When this time has elapsed, the calibration alarm is triggered to signal that a 
calibration is due.

Calibration alarm

The calibration alarm is triggered when the time set on the calibration timer 
has elapsed and generates a corresponding signal on the device. On device 
versions with a display, the calibration alarm flashes in the header of the dis-
play.

Summary of Contents for digiLine CR HT10

Page 1: ...20276340T90Z001K000 V2 01 EN 00691450 JUMO digiLine CR Intelligent electronic components with IO Link interfa ce for conductive conductivity sensors Operating Manual...

Page 2: ......

Page 3: ...0 3 Device Description 11 3 1 Introduction 11 3 2 Block diagram 11 3 3 Device setup 12 3 4 Description 14 4 Identifying the device version 17 4 1 Order details 17 4 1 1 Head transmitter 202763 17 4 1...

Page 4: ...al operation in device versions with a display 45 9 6 Calibration logbook 48 9 7 Evaluation criteria for calibration 48 10 Troubleshooting in the event of faults 49 11 Data overview 51 11 1 General In...

Page 5: ...77 14 2 Sensor replacement on device versions with a separate sensor 77 15 Technical data 79 15 1 IO Link interface 79 15 2 Analog inputs sensor connection side 79 15 3 Electrical data 80 15 4 Case 8...

Page 6: ...Contents...

Page 7: ...ts 1 1 2 Note symbols NOTE This symbol refers to important information about the product its handling or additional benefits 1 2 Intended use The device described in these instructions is used to meas...

Page 8: ...is always necessary to provide safety devices that are independent of the device and to allow settings to be made only by technical personnel CAUTION JUMO sensors with digiLine electronics must be ca...

Page 9: ...ter for repair when returning goods Do not forget to state the following Description of the application Description of the error that has occurred The accompanying letter for repair is linked to www j...

Page 10: ...due to friction Use only packaging intended specifically for ESD sensitive assemblies components These must consist of conductive plastics Keep in mind that the manufacturer assumes no liability for...

Page 11: ...sensor the JUMO digiLine electronics can be disconnected from the sensor and the intact compo nents reused In the device version as head transmitter disconnecting the sensor from the JUMO digiLine el...

Page 12: ...M12 plug connector for output input signals or inter face connection depending on device version 5 Holder for wall pipe and DIN rail mounting 6 Housing opening for USB interface closed with vent ing...

Page 13: ...ce version with display and membrane keyboard Device version without display and membrane key board 1 JUMO digiLine device frontCR with operating panel 2 Display 3 Operating keys 1 JUMO digiLine devic...

Page 14: ...a set calibration interval has lapsed is able to trigger a reminder for the sensor calibration due for the relative cell constant on the master The calibration interval setting can be changed via the...

Page 15: ...DSM stands for Digital Sensor Management can be used to manage cali brate and test JUMO digiLine electronics on the PC In addition it serves as a configuration tool for the JUMO digiLine electronics T...

Page 16: ...3 Device Description 16...

Page 17: ...out display 10 With display 4 Version 8 JUMO standard 9 Customer specific version 5 Language 01 German 02 English 6 Cell constant 0001 0 01 1 cm 0010 0 1 1 cm 0100 1 0 1 cm 7 Measuring insert 1003 1 P...

Page 18: ...9 Customer specific version 5 Language 01 German 02 English 6 Cell constant 0010 0 1 1 cm 0100 1 0 1 cm 7 Measuring insert 1003 1 Pt100 in two wire circuit 1005 1 Pt1000 in two wire circuit 8 Process...

Page 19: ...an 02 English 6 Cell constant 0001 0 01 1 cm 0010 0 1 1 cm 7 Measuring insert 1003 1 Pt100 in two wire circuit 1005 1 Pt1000 in two wire circuit 8 Process connection 104 Thread G 1 2Aa 105 Thread G 3...

Page 20: ...4 Identifying the device version 20 1 2 3 4 5 6 7 Order code Order example 202765 10 10 8 01 0010 1003 8 9 10 11 613 31 31 JUMO...

Page 21: ...on 8 JUMO standard 9 Customer specific version 5 Language 01 German 02 English 6 Cell constant 0001 0 01 1 cm 0010 0 1 1 cm 7 Measuring insert 1003 1 Pt100 in two wire circuit 1005 1 Pt1000 in two wir...

Page 22: ...th display 4 Version 8 JUMO standard 9 Customer specific version 5 Language 01 German 02 English 6 Cell constant 0001 0 01 1 cm 0010 0 1 1 cm 7 Measuring insert 1003 1 Pt100 in two wire circuit 1005 1...

Page 23: ...8 JUMO standard 9 Customer specific version 5 Language 01 German 02 English 6 Cell constant 0100 1 0 1 cm 7 Measuring insert 1003 1 Pt100 in two wire circuit 1005 1 Pt1000 in two wire circuit 8 Proce...

Page 24: ...display 4 Version 8 JUMO standard 9 Customer specific version 5 Language 01 German 02 English 6 Cell constant 0500 0 5 1 cm 7 Measuring insert 1005 1 Pt1000 in two wire circuit 8 Process connection 99...

Page 25: ...English 1 2 3 4 5 Order code Order example 202762 10 10 8 01 Type Part no JUMO DSM software Digital Sensor Management 00655787 Sensor connection cable with M12 cable socket 8 pole with the ferrules a...

Page 26: ...4 Identifying the device version 26...

Page 27: ...nt such as motors and transformers should be avoided The ambient temperature at the mount ing site and the relative humidity must correspond to the technical data Aggressive gases and vapors have a ne...

Page 28: ...5 Mounting 28 Dimensions of the mounting plate for wall pipe and DIN rail mounting 87 63 3 29 8 49 9 76 4 39 2 37 9 4 5...

Page 29: ...29 5 Mounting 5 2 2 Device versions as head transmitter Dimensions of the JUMO digiLine electronic components 85 56 5 85 71 80...

Page 30: ...105 Thread G 3 4A Process connection 604 Taper socket DN25 41 44 5 25 Process connection PVC body material Stainless steel sensor 6 37 78 20 171 161 6 37 41 44 5 25 PVC body material Process connectio...

Page 31: ...mounting 1 Wall mounting surface 2 Mounting plate included in the scope of delivery of the JUMO digiLine CR 3 JUMO digiLine CR DIN rail mounting 1 DIN rail 2 Mounting plate included in the scope of d...

Page 32: ...holders that accommodate the corresponding sensor type for your device Given the variety of different sensor types available in conjunction with the JUMO digiLineCRas head transmitter there is a corr...

Page 33: ...e tightened to a maxi mum torque of 0 5 Nm The pin assignment shown here is intended primarily to provide an overview and serve as an aid when troubleshooting Connection terminal assignment M12 x 1 ro...

Page 34: ...r electrode 1 Socket Connection side 2 Gray Inner electrode 1 3 Yellow Temperature 1 4 Green Temperature 2 5 Pink Inner electrode 2 6 blue Outer electrode 2 7 Brown Temperature 3 8 White Shield 2 1 3...

Page 35: ...olation JUMO digiLine CR with IO Link interface USB interface Data DC 5 V Voltage supply IO Link DC 24 V IO Link binary output 1 IO Link communication port binary outpup 2 DC 50 V AC 30 V DC 50 V AC 3...

Page 36: ...output Switch operation with 2 switching outputs p switching PNP p switching PNP n switching NPN n switching NPN L L C Q IO Link I Q OUT2 BU BK WH BN 1 3 4 2 L C Q OUT1 I Q OUT2 L BU BK BN WH 1 3 4 2...

Page 37: ...ring Tools Measuring mode After the JUMO digiLine has been switched onCRthe JUMO logo appears briefly on the display in device versions with a display The device then switches to the measuring mode Th...

Page 38: ...the end of the line after menu entries indicate that additional submenus are available If the number of menu entries in a menu exceeds the number of display lines a scroll bar appears at the right edg...

Page 39: ...g key to return to the menu hierarchy or measured value display Changing password Accessing a menu Device menu Log on Log out Change password Passwords can only be changed for logged in users First lo...

Page 40: ...7 2 4 Service Maintenance functions and functions for setting the device hardware are found in the Service menu Contrast Sets the display contrast in 10 steps adjustable by means of the Up and Down o...

Page 41: ...ors with JUMO digiLine electronics can disrupt proper execution of the downstream process or cause damage For this reason it is always necessary to provide safety devices that are independent of the d...

Page 42: ...current measured values on a PC JUMO DSM software operating manual Functional check on an IO Link master The JUMO digiLineCRfunctions can be checked with the aid of a PLC and appropriate software on a...

Page 43: ...stant per measuring range has been set a separate calibration of the cell constant must be performed for each measuring range chapter 13 3 1 CR input resistivity conductivity page 71 Temperature coeff...

Page 44: ...e at least 20 C higher than the starting temperature of the TC curve The two values are requested at the start of the TC curve calibration and must be entered by the user The reference temperature mus...

Page 45: ...the sensor The calculated calibration values and the data in the calibration logbook are saved in the JUMO digiLine electronics following successful calibration The procedure for calibrating with a PC...

Page 46: ...ocedure for calibrating the temperature coefficient TC 1 Start calibration of the temperature coefficient Device menu Calibrate Calibration of temperature coefficient 2 Use the Up and Down operating k...

Page 47: ...change the displayed starting temperature and confirm entry of the value by pressing the OK operating key Keep in mind that the starting and end temperature must differ by at least 20 C 4 Use the Up a...

Page 48: ...lues are also documented The following data are retained in the logbook Date and time Calibration values determined or entered Calibration mode true calibration manual entry of calibration values Cali...

Page 49: ...ck the following items All plug in and terminal connections must be made correctly and be tight You can use a PLC togeth er with your engineering system for a function check of communication via the i...

Page 50: ...10 Troubleshooting in the event of faults 50...

Page 51: ...ware version of the input proces sor Hardware version Sensor type Article information on the sensor mounted on the JUMO digiLine electronics is entered in these fields by the manufacturer during produ...

Page 52: ...t can also be re trieved by the IO Link master Sensor stress The Sensor stress value reflects the current level of stress on the sensor from rapidly changing temperatures and aggressive media high con...

Page 53: ...unter reading at startup on a JUMO digiLine master Drag indicator for temperature Lowest temperature value Data on the highest or lowest temperature values that occurred inside the de vice in the cour...

Page 54: ...unning time on calibra tion timer Elapsed time on calibration timer When this time has elapsed the calibration alarm is triggered to signal that a calibration is due Calibration alarm The calibration...

Page 55: ...o cess value TFLOAT Sensor measuring range 0 Temperature pro cess value TFLOAT Sensor measuring range 0 Measuring range selection TUINT8 bit field 0x00 MR 1 0x01 MR 2 0x02 MR 3 0x03 MR 4 0 Status TUIN...

Page 56: ...Measuring range selection TUINT8 bit field 0x00 MR 1 0x01 MR 2 0x02 MR 3 0x03 MR 4 0 Status TUINT16 bit field Bit 0 Invalid conductivi ty process value Bit 1 Invalid tempera ture process value Bit 2...

Page 57: ...range Default Description Measuring range selection TUINT8 0x00 MR 1 0x01 MR 2 0x02 MR 3 0x03 MR 4 Compensation temperature TFLOAT Compensation temperature ac quired by IO Link master for trans fer t...

Page 58: ...t mode 121 0 TENUM TENUM values 0x00 One CC for all MR 0x01 One CC for each MR 0x00 RW Contamination detection 122 0 TENUM TENUM values 0x00 Off 0x01 On 0x00 RW Cable break de tection 123 0 TENUM TENU...

Page 59: ...C linear 0x02 TC curve 0x03 nat waters 0x04 nat waters ex tended 0x05 TDS 0x06 ASTM neutral 0x07 ASTM acidic 0x08 ASTM alkaline 0x01 RW Temperature co efficient 3 TFLOAT 0 to 8 K 2 4 RW Offset 4 TFLOA...

Page 60: ...emperature 4 9 TFLOAT 20 to 150 C 0 RW Temperature co efficient 4 10 TFLOAT 0 to 8 0 RW Temperature 5 11 TFLOAT 20 to 150 C 0 RW Temperature co efficient 5 12 TFLOAT 0 to 8 0 RW Temperature input Desi...

Page 61: ...lt Ac cess righta a RW Read and write access RO Read access only WO Write access only Description CIP temperature 320 0 TFLOAT 20 to 150 C 80 RW CIP cycle dura tion 321 0 TUINT16 0 to 65535 s 1800 RW...

Page 62: ...alues 0x00 C 0x01 F 0x00 RW Display start scal ing 344 to 347 forMR 1 to 4 1 TFLOAT 0 to display end scal ing 0 RW Display end scal ing 2 TFLOAT Display start to 9999 100 RW Conductivity dis play form...

Page 63: ...e range Default Ac cess righta a RW Read and write access RO Read access only WO Write access only Description Enablecalibration of relative time constant 360 0 TENUM TENUM values 0x00 Locked 0x01 Ena...

Page 64: ...value 0x01 Limit value 1 0x02 Limit value 2 0x03 Sensor fault 0x04 Calibration timer 0x05 Calibration ac tive Switch ing out put 1 0x01 Switch ing out put 2 0x02 RW Inversion 361 2 TENUM TENUM values...

Page 65: ...ty 0x02 Comp conduct ivity 0x02 Self locking 2 TENUM TENUM values 0x00 Off 0x01 Acknowledg ment if inactive 0x02 Acknowledgm ent always 0x00 Startup alarm suppression mode after power on 3 TENUM TENUM...

Page 66: ...NT16 0 to 9999 s 0 RW Switch off delay 7 TUINT16 0 to 9999 s 0 RW Pulse time 8 TUINT16 0 to 9999 s 0 RW Response at hold 9 TENUM TENUM values 0x00 Inactive 0x01 Active 0x02 Frozen 0x02 RW Response in...

Page 67: ...application 2 RW Designation Index Sub index Data type Value range Ac cess right Description Operating Hours Counter 3000 0 TUINT32 RO Drag indicator tem perature process val ue min 3040 0 TFLOAT 50...

Page 68: ...perature input invalid Yes Bit1 Process data invalid 4 failure 0x1000 Standard event Yes a common switch Ap plication specific events Error Compensation temperature invalid Yes Bit2 4 failure 0x8C20 S...

Page 69: ...he process data is invalid In order to determine the precise cause the process value or status bits can be evaluated Process value status See chapter 12 1 Process data page 55 Error in cali bration da...

Page 70: ...12 IO Link data 70...

Page 71: ...erature configuration item Via interface Compensation temperature is transferred by master Temperature input The integrated temperature probe of the sensor supplies the compensation temperature Manual...

Page 72: ...nd TDS compensation The temperature coefficient is a measure of the temperature de pendence of the electrolytic conductivity of a liquid It is used to compensate for the effect of temperature when mea...

Page 73: ...or the connected resistance thermometer Configuration item Selection setting op tion Explanation output signal Limit value 1 Limit value 2 Sensor fault Calibration timer Calibration active Digital sig...

Page 74: ...ess level 7 CIP temperature 20 to 150 C Temperature thresholds for identifying CIP SIP cycles If the CIP SIP cycle takes place above one of these values for the set duration of a CIP SIP cycle the val...

Page 75: ...en remains logged in for the entire length of the session chapter 7 2 1 Log on Log out page 39 Display type Normal Large display Bargraph In the normal and large display 2 values are shown on the dis...

Page 76: ...display below the main value The appearance of the display can be set in the display type higher up in this table Configuration item Selection setting op tion Explanation Configuration item Selection...

Page 77: ...NOTE Sensor replacement is not possible on JUMO digiLine electronics in device versions as a head transmit ter Here replacement of the entire module with sensor and electronics is required Replacemen...

Page 78: ...14 Operation maintenance and care 78...

Page 79: ...esistant to overload Yes protected against polarity reversal Yes Ampacity of the switching outputs 100 mA in each case Voltage drop of the switching outputs max 2 V in each case Measuring range Pt100...

Page 80: ...g range span Voltage supplyab DC 18 to 30 V Power current consumption Digital outputs without load 1 5 W Load per digital output up to 100 mA 7 5 W Electromagnetic compatibility EMC DIN EN 61326 1 DIN...

Page 81: ...humidity 100 condensing Ambient temperature 20 to 60 C Storage temperature 25 to 80 C Shock resistance DIN EN 60654 3 Acceleration 40 m s2 Duration Duration 5 ms Vibration resistance IEC 61298 3 Freq...

Page 82: ...lowing table CAUTION In the case of head transmitters heat emitted from the system can exceed the admissible tem perature of the head transmitter Make sure that the head transmitter used is operated w...

Page 83: ......

Page 84: ...ers Road East Syracuse NY 13057 USA Delivery address Mackenrodtstra e 14 36039 Fulda Germany Phone Fax Email Internet 44 1279 63 55 33 44 1279 62 50 29 sales jumo co uk www jumo co uk Phone Fax Email...

Reviews: