– 51 –
ENGLISH
15. How to connect the material edge sensor
For SC-922, a commercially available photoelectric sensor can be connected and used as a material end sensor.
A connection example is shown below.
Pn No.
Sgnal
Remarks
2
GND
0V
11
OPI16
Sensor nput
13
+24V
Power source
1) Connect the material end sensor to the connector
1
(Molex, 22P).
For 2-wre system, connect 0 V and the sensor
nput to pn 2 and pn 11, respectvely.
For 3-wre system, connect 0 V, the sensor nput,
and 24 V to pn 2, pn 11, and pn 13, respectvely.
2-wire
system
2) Insert the connector
1
that was connected n
the step 1 nto the connector
2
(CN51, 22P) of
SC-922.
3) Pass these cables through the cable clamp and
fasten them wth the cord of the materal end
sensor wth the cable band
3
mounted on the
side face of the box.
4) Connect CN51-11 (display No. i24) to the mate
-
ral edge sensor nput referrng to
lection of the optional input/output function
(Function setting No. 12)" p.34.
(Caution) 1. Be sure to turn off the power before
connection.
2. use a 24 V-ready material end sensor.
3. refer to
for how to use the material edge sen-
sor.
1
3
2
(Cable
band)
(CN51)
3-wire