– 46 –
£££££
Number of stitches for teaching replay (Function setting No. 113)
The number of stitches is selected for teaching replay when corner teaching is carried out (measuring the num-
ber of stitches for unilateral needle sewing).
0: The number of replay stitches coincides with that of measured stitches.
1: The number of replay stitches is less by 1 than that of measured stitches.
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
¢¢¢¢¢
Left Bobbin thread counter function (Function setting No. 114)
When the IP-100 is connected, this function is used to stop/use the left bobbin thread counter.
0: off Left bobbin thread counter function disabled
1: on Left bobbin thread counter function enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
Right bobbin thread counter function (Function setting No. 115)
When the IP-100 is connected, this function is used to stop/use the right bobbin thread counter
0: off Right bobbin thread counter function disabled
1: on Right bobbin thread counter function enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
§§§§§
Selection of corner teaching start switch (Function setting No. 116)
When the IP-100 is connected, the switch to start in-corner sewing is selected during corner pattern sewing.
0: No function
1: Left needle selector switch
2: Right needle selector switch
3: Teaching switch
4: Optional switch
5: Knee switch, presser lifter switch
6: No function (Don’t care.)
* When 1: left needle selector switch, 2: right needle selector switch, or 3: teaching switch is selected for the in-
corner selector switch, set No.111 unilateral needle selection function (corner pattern) at 0 (function disabled),
without fail.
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
1
1
3
0
1
1
4
1
1
1
5
1
1
1
6
5
55