– 27 –
(3) Function setting list
No.
Item
Description
Setting range
1
Soft start
The number of stitches to be sewn at a low speed when the soft-start
0 to 9
34
function
function is used at the start of sewing.
(Stitches)
0 : Soft-start function is not operative.
2
Material end
Material end sensor function (used in case of without panel).
0/1
34
sensor
0 : Material end detection function is not operative
function
1 : After detecting material end, the specified number of stitches (No. 4) will
be sewn, and the sewing machine will stop.
3
Thread trimming
Thread trimming function by material end sensor (used in case of without panel).
0/1
34
function by
0 : Automatic thread trimming function after detection of material end is not
material end
operative.
sensor
1 : After detecting material end, the specified number of stitches (No. 4) will
be sewn, and the sewing machine will stop and perform automatic
thread trimming.
4
Number of
Number of stitches for material end sensor (used in case of without panel).
0 to 19
34
stitches for
Number of stitches from detection of material end to stop of the sewing
(Stitches)
material end
machine.
sensor
5
Flicker reducing
Flicker reducing function (If the hand lamp flickers).
0 to 8
34
function
0 : Flicker reducing function is not operative.
1 : Less effective . 8 : Highly effective
6
Bobbin thread
Bobbin thread counting function
0/1
34
counting
0 : Bobbin thread counting function is not operative.
function
1 : Bobbin thread counting function is operative.
7
Unit of bobbin
Unit of bobbin thread counting down
0 to 2
thread counting
0 : Count/10 stitches
down
1 : Count/15 stitches
2 : Count/20 stitches
8
Number of
Sewing speed of reverse feed stitching
180 to 3000
rotation of
(r.p.m)
reverse feed
stitching
9
Thread
Thread trimming prohibiting function (used in case of without panel).
0/1
34
trimming
0 :Thread trimming prohibiting function is not operative.
prohibiting
1 : Thread trimming is prohibited.
function
(Output of solenoid is prohibited. : Thread trimmer and wiper)
10
Setting of
Position of needle bar is specified when the sewing machine stops.
0/1
34
needle bar
0 : Predetermined lowest position
stop position
1 : Predetermined highest position
when the sewing
machine stops.
11
Click sound of
Click sound of key switch mounted on PSC is specified.
0/1
34
key switch
0 : Click is not operative.
mounted on
1 : Click is operative.
PSC
12
Optinal switch
Switching of function of optional switch.
0 to 8
35
function
0 : No function
selection
1 : Needle up/down compensating stitching
2 : Back compensating stitching
3 : Function of canceling once reverse feed stitching at the end of sewing
4 : Thread trimming function
5 : Presser foot lifting function
6 : One stitch compensating stitching
7 : Function of simultaneously canceling reverse feed stitching at the start
and end of sewing
8 : Neutral presser lifting changeover function
13
Function of
Function of prohibiting start of the sewing machine by bobbin thread counting
0 to 2
43
prohibiting
0 : When counting is out (-1 or less) Function of prohibiting start of the
start of the
sewing machine is not operative.
sewing
1 : When counting is out (-1 or less) Function of prohibiting start of the
machine by
sewing machine is operative.
bobbin thread
2 : When counting is out (-1 or less) Function of forcibly prohibiting start of
counter
the sewing machine is operative.
14
Sewing
Counting function of sewing (number of completion of process)
0/1
35
counter
0 : Sewing counter function is not operative.
1 : Sewing counter function is operative.
15
Number of times
Number of times of detection of run-out of bobbin thread remaining amount
0 to 19
of detection of
0 : Function of bobbin thread remaining amount is not operative.
run-out of
1 to 19 : Number of times during which the signal is not made even if run-out
bobbin thread
of bobbin thread remaining amount is detected.
remaining
amount
1
0
2
0
3
0
4
5
5
0
6
1
7
0
8
1
9
0
0
9
0
1
0
0
1
1
1
1
2
0
1
3
0
1
4
0
1
5
1
Indication of
Ref.
function setting
page