– 19 –
2) Matters that demand special attention regarding the operation panel, IP-100
1. Kind of IP-100
For the operation panel, IP-100, there are several kinds of types in accordance with the specifications.
Types that can be used for SC-910 are TYPE-B and TYPE-C. The product is TYPE B0A or TYPE C0A which is
indicated on the name plate seal located in the rear of the panel case.
Brackets for installing panel for both types are different from each other.
There is the jumper wire W1 (side of RVR1 variable resistor) on the circuit board. Set the W1 setting to 2-3 for
both types.
Type name plate seal
Setting of W1
TYPE B0A
2-3 pin setting (lower side)
TYPE C0A
2-3 pin setting (lower side)
(Caution) When setting is wrong, LCD screen display is not properly performed.
2. Matters that demand special attention when disassembling the operation panel
Operation panel, IP-100 is constructed with precision components.
Leave the action such as disassembling the panel case or the like to our service department since injury by
electric shock or failure of panel will be caused.
If the force more than expected is applied when disassembling the panel case, it may be damaged since it is
made of the plastic molding.
Especially when performing disassembling (opening/closing) the front panel and the rear panel in the state that
the smart media cover attached to the rear case is closed, the small-sized switch mounted on the inside of the
printed circuit board interferes with the smart media cover and may be damaged. So, be careful.
It is necessary to assemble all screws used in the operation panel with tightening torque of 0.56Ncm.
(Excluding screws to fix it on the machine head and to fix the earth wire.)
3. Prohibition of the change of DIP switch setting
Do not perform the changeover of DIP switches since the guarantee of control program and stored data cannot
be performed.
It is not necessary to operate these switches since they are all changeover switches for the production by the
manufacturers.
(Caution) The 4-string DIP switches are not exposed unless the operation panel case is disassembled.
W1
1
2
3
TYPE B0A, C0A