– 53 –
3) It is possible to set the method to count the number of pieces produced. (Function setting No. J13)
J13
0: OFF
1: Ascending order
2: Descending order
3: Ascending order (audio notification)
4: Descending order (audio notification)
The audio notification is given when the function setting number "J05 Audio setting" is set to "ON" and
"R" is displayed on the operation panel.
In the case the ascending order is selected, the audio message "Set value is reached on the counter" will
be given when the daily target number of pieces that is set with the function setting number "U01 Daily
target" is reached.
In the case the descending order is selected, the audio message will be given when the counter reaches
zero (0).
4) It is possible to reset the No. of pcs. counter by keeping
❸
and
❹
held pressed simultane-
ously.
While the ascending order is selected, the counter is reset to zero (0).
While the descending order is selected, the counter is reset to the target value set with the function set
-
ting number "U01 Daily target".
5) Press
❶
if you want to return to the function setting screen.
Function setting parameters cannot be changed while the No. of pcs. counter is displayed on the opera
-
tion panel including operation of buttons
❼
,
❽
,
❾
.
If you want to change the setting of the parameter, press
❶
once to return to the function setting
screen, and change the parameter appropriately referring to
Summary of Contents for MO-6800D/DD20 Series
Page 1: ...MO 6800S D DD20 Series INSTRUCTION MANUAL...
Page 20: ...17 MO 6814 44H MO 6816...
Page 21: ...18 MO 6816 50H MO 6816 60H...
Page 74: ...71 1200 Unit mm Difference 2 10 TABLE DRAWING Black scale marker line A A B B...
Page 76: ...73 Auxiliary table for fully sunken type table Unit mm Difference 2 Weight 4 25 kg 5...