– 48 –
Function setting No. P051: Used for setting the continuing number of stitches to be sewn before the rear
suction operation stops after the material has passed the intermediate sensor.
P051 Setting range: 0 - 50 stitches
(Caution) This function setting number is enabled only when "DD22" is selected with the
"P125 Model selection (setting of this function is enabled under the Service lev
-
el).
Function setting No. P052: Used for setting the delaying number of stitches to be sewn before the rear
suction operation is started after the material has passed the intermediate sensor. If the "P022 Interme
-
diate sensor" is set to "OFF", the sewing machine will stop or carry out rear suction operation after it has
sewn this number of stitches after the material has passed the front sensor.
P052 Setting range: 0 - 50 stitches
(Caution) This function setting number is enabled only when "DD22" is selected with the
"P125 Model selection (setting of this function is enabled under the Service lev
-
el).
Function setting No. P053: Used for setting the duration to be elapsed before the rear suction operation
is stopped after the sewing machine has started the rear thread trimming.
P053 Setting range: 0 - 2000 [ms]
(Caution) This function setting number is enabled only when "DD23" is selected with the
"P125 Model selection (setting of this function is enabled under the Service lev
-
el). If the rear suction is set to "OFF", the rear suction operation will not be car
-
ried out.
⑫
Selection of the auto-lifter function (Function setting No. P066)
Type of the auto-lifter operation can be selected.
P066 0: OFF
1: Front lifting
2: Rear lifting
3: Front and rear lifting
The setting of the auto-lifter function can also be changed by pressing button
❽
on the operation
panel.
When the front lifting is selected,
K
is displayed on the operation panel.
When the rear lifting is selected,
L
is displayed on the operation panel.
When the front and rear lifting is selected,
K
and
L
are displayed on the operation panel.
Function setting No. P069: Used for setting the duration to be elapsed before the front lifter comes down
after it has gone up.
P069 Setting range: 50 - 2000 [ms]
Function setting No. P070: Used for setting the delaying time to be elapsed until the rear lifting is started.
P070 Setting range: 0 - 2000 [ms]
⑬
Selection of the grid pattern fabric (Function setting No. P089)
Select this function setting number when sewing a fabric with holes arranged in a grid pattern.
P089 0: General fabric
1: Grid pattern fabric
Function setting No. P033: Used for setting the number of stitches to allow the sensor to skip the holes
arranged in a grid pattern.
P033 Setting range: 0 - 50 stitches
(Caution) Set an appropriate number of stitches in accordance with the hole configuration.
The initial value of the function setting number P033 is "0" when "DD22" is selected or "8" when "DD23"
is selected with the "P125 Model selection (setting of this function is enabled under the Service level)
Summary of Contents for MO-6800D/DD20 Series
Page 1: ...MO 6800S D DD20 Series INSTRUCTION MANUAL...
Page 20: ...17 MO 6814 44H MO 6816...
Page 21: ...18 MO 6816 50H MO 6816 60H...
Page 74: ...71 1200 Unit mm Difference 2 10 TABLE DRAWING Black scale marker line A A B B...
Page 76: ...73 Auxiliary table for fully sunken type table Unit mm Difference 2 Weight 4 25 kg 5...