– 39 –
No
Item
Description
Range
Initial value
DD22
DD23
U01
Daily target
This function setting number is used for setting the daily target number of products to be sewn.
(Unit: Piece)
0000-9999
100
100
U02
Number of times to count a piece of
product
This function setting number is used for setting the number of times of thread trimming to be
counted before the number of products increases by one. (Unit: Number of times)
1-50
10
10
U03
Working hours (Start time - )
This function setting number is used for setting the start time of sewing work.
00:00
~
23:59
8:00
8:00
U04
Working hours ( - Ending time)
This function setting number is used for setting the ending time of sewing work.
* This setting is used for the audio guidance.
00:00
~
23:59
17:00
17:00
U05
Break time 1 (Start time - )
This function setting number is used for setting the start time and ending time of a break.
This setting is used for the audio guidance.
* If no break time is provided, set U05 to "00:00". In this case, no audio guidance is provided.
(Caution)
* If the break times 1, 2 and 3 are provided, it will be necessary to enter the start time and
ending time of those break times in the descending order.
* If you enter a break time that is not included in the working hours, no audio guidance will be
given.
00:00
~
23:59
00:00
00:00
U06
Break time 1 ( - Ending time)
00:00
~
23:59
00:00
00:00
U07
Break time 2 (Start time - )
00:00
~
23:59
00:00
00:00
U08
Break time 2 ( - Ending time)
00:00
~
23:59
00:00
00:00
U09
Break time 3 (Start time - )
00:00
~
23:59
00:00
00:00
U10
Break time 3 ( - Ending time)
00:00
~
23:59
00:00
00:00
N01
Main software version
This function setting number is used for displaying the main software version.
N02
Operation panel software version
This function setting number is used for displaying the operation panel software version.
N14
Sub software version
This function setting number is used for displaying the version of the software that is used by
the sub CPU.
N20
Voice language version
This function setting number is used for displaying the version of the language of the audio file.
Summary of Contents for MO-6800D/DD20 Series
Page 1: ...MO 6800S D DD20 Series INSTRUCTION MANUAL...
Page 20: ...17 MO 6814 44H MO 6816...
Page 21: ...18 MO 6816 50H MO 6816 60H...
Page 74: ...71 1200 Unit mm Difference 2 10 TABLE DRAWING Black scale marker line A A B B...
Page 76: ...73 Auxiliary table for fully sunken type table Unit mm Difference 2 Weight 4 25 kg 5...