– 28 –
4
B
3) Turn OFF the power switch, and turn ON the power switch again to return to the normal mode.
Be sure to re-turn ON the power switch when one or more seconds have passed after turning it
Off.
(If the ON-OFF operation is carried out faster than the above, the setting may not change normal
-
ly.)
Pedal sensor with two springs
located at the back part of the
pedal type is PFL, and that with
one spring type is KFL. Set the
pedal sensor to PFL when lifting
the presser foot by depressing the
back part of the pedal.
1) Pressing switch
4
, turn ON the power
switch.
2) Compensated value is displayed on indica-
tor
B
.
1. At this time, the pedal sensor
does not work properly if the
pedal is depressed. Do not
place the foot or any object
on the pedal. Warning sound
"blips" and the correct compen
-
sation value is not displayed.
2. If any display ("-0-" or "-8-")
other than a numeric value ap
-
pears on indicator
B
, refer to
the Engineer's Manual.
9. SELECTION Of THE pEdAL SpECIfICATIONS
When the pedal sensor has been replaced, change the set value of function setting No. 50 according to the
newly connected pedal specifications.
0 : KFL
1 : PFL
8. AUTOMATIC COMpENSATION Of NEUTRAL pOINT Of THE pEdAL
SENSOR
Whenever the pedal sensor, spring, etc. are replaced, be sure to perform following operation :