– 29 –
* Do not change the set values with asterisk (
*
) mark as they are functions for maintenance. If the standard set value set at the
time of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
If it is necessary to change the set value, please purchase the Engineer’s Manual and follow the instructions.
7. Function setting list
No.
Item
Descrpton
Settng range
Indcaton of functon settng Ref. page
Soft start
functon
The number of sttches to be sewn at a low speed when the soft-
start functon s used at the start of sewng.
0 : The functon s not selected.
to 9 : The number of sttches to be sewn under the soft-
start mode.
0 to 9
(Sttches)
1
0
33
2 Materal end
sensor functon
Materal end sensor functon.
0 : Materal end detecton functon s not operatve.
: After detectng materal end, the specfed number of
sttches (No. 4) wll be sewn, and the sewng machne wll
stop.
0/
2
0
33
3 Thread trmmng
functon by
materal end
sensor
Thread trmmng functon by materal end sensor.
0 : Automatc thread trmmng functon after detecton of ma-
teral end s not operatve.
: After detectng materal end, the specfed number of
sttches (No. 4) wll be sewn, and the sewng machne wll
stop and perform automatc thread trmmng.
0/
3
0
33
4 Number of
sttches for
materal end
sensor
Number of sttches for materal end sensor.
Number of sttches from detecton of materal end to stop of the
sewng machne.
0 to 9
(Sttches)
4
5
33
5 Flcker reducng
functon
Flcker reducng functon
0 : Flcker reducng functon s not operatve.
: Flcker reducng functon s effectve
0/
5
0
33
6 Bobbn thread
countng
functon
Bobbn thread countng functon
0 : Bobbn thread countng functon s not operatve.
: Bobbn thread countng functon s operatve.
0/
6
1
33
*
7 Unt of bobbn
thread countng
down
Unt of bobbn thread countng down
0 : Count/0 sttches
: Count/5 sttches
2 : Count/20 sttches
3 : Count/thread trmmng
0 to 3
7
0
*
8 Number of
rotaton of
reverse feed
sttchng
Sewng speed of reverse feed sttchng
50 to 3,000
(st/mn)
8
1 9 0 0
9 Thread
trmmng
prohbtng
functon
Thread trmmng prohbtng functon.
0 : Thread trmmng s effectve.
: Thread trmmng s prohbted.
(Output of solenod s prohbted. : Thread trmmer and wper)
0/
9
0
33
0 Settng of
needle bar stop
poston when
the sewng
machne stops.
Poston of needle bar s specfed when the sewng machne
stops.
0: The needle bar stops at ts lower poston.
: The needle bar stops at ts upper poston.
0/
1 0
0
33
Operaton
confirmation
sound for
operaton panel
Operation confirmation sound for operation panel
0 : Operation confirmation sound is not generated
1 : Operation confirmation sound is generated.
0/
1 1
1
33
2 Optnal swtch
functon
selecton
Swtchng of functon of optonal swtch.
1 2
o P t _
34
*
3 Functon of
prohbtng start
of the sewng
machne by
bobbn thread
counter
Functon of prohbtng start of the sewng machne by bobbn thread countng
0 : When countng s out (- or less) Functon of prohbtng
start of the sewng machne s not operatve.
: When countng s out (- or less) Functon of prohbtng
start of the sewng machne after thread trmmng s op-
eratve.
2 : When countng s out (- or less), the sewng machne
stops once. Functon of prohbtng start of the sewng
machne after thread trmmng s operatve.
0 to 2
1 3
0
4 Sewng counter Countng functon of sewng (number of completon of process)
0 : Sewng counter functon s not operatve.
: Sewng counter functon s operatve. (Every tme thread
trmmng s performed)
2 : Wth the sewng countng swtch nput functon
0 to 2
1 4
1
37
5 Thread wpng
functon after
thread trmmng
Thread wiping operation after thread trimming is specified.
0 : Thread wpng s not carred out after thread trmmng
: Thread wpng s carred out after thread trmmng
0/
1 5
1
2 Functon of
automatc
presser foot
lftng at pedal's
neutral poston
Functon of lftng presser foot when the pedal s n neutral pos-
ton.
0 : Functon of neutral automatc presser lftng s not opera-
tve.
: Selecton of functon of neutral presser lftng.
0/
2 1
0
37