– 84 –
No.
Name
Selection item
Setting
range
Unit &
Meaning
Initial value
HS3020RSZ
GS3020RSZ
HS3020RSW
GS3020RSW
U105 Position of the intermediate presser /
wiper operation
0: Wiper operates above the interme-
diate presser
1: Wiper operates above the inter-
mediate presser (at the lower end
position of intermediate presser)
2: Wiper operates under the interme-
diate presser
0 to 2
-
1
U108 With / without the air pressure detec-
tion
0: Without
1: With
0 to 1
-
1
U112 Setting of the lower position of inter-
mediate presser
0 to 7.0
0.1 mm
3.5
U129 With / without the needle cooler con-
trol
0: Without
1: With
0 to 1
-
1
U145 Count completion closing time (for
VER. update)
0 to 99
1 sec
0
U170 Selection of unit for enlargement /
reduction ratio
0: 0.01%
1: 0.1%
0 to 1
-
1
U171 Reference point for enlargement /
reduction
0: Reference point for enlargement /
reduction in VDT
1: 2nd origin
2: Mechanical origin
3: Sewing starting position
0 to 3
-
0
U206 Constant speed, feed ratio (5 mm or
less)
70 to 100%
1%
100
U207 Constant speed, feed ratio (more than
5 mm)
70 to 100%
1%
100
U245
Number of stitches to be sewn before
the grease runs out (higher-order 16
bits)
Number of counts increases on a
stitch-by-stitch basis
Clearing is only effective
0
-
0
U263
Offset at the position before cutting
(outward)
-100 to 100
1 pulse
0
U264
Offset at the position before cutting
(Inward)
-100 to 100
1 pulse
0