OPERATION 

The Nano SPY can only be used with the My Sirius software hosted on a Web platform and with a Nano SPY 

Link. See MySirius online help for Nano Spy configuration. 

 

a)

 

Off state 

As delivered, the Nano SPY is turned off. It can neither emit nor receive signals. 

 

b)

 

Activation 

 
 
 
 
 
 
Once activated, the le Nano SPY automatically declares itself in MySirius if it is contact with a Link. It starts to 

measure and transmit its measurements to My Sirius, at the frequency defined in MySirius, then flashes 

regularly as a function of its status.  

c)

 

Turning Off 

 

 

d)

 

Actions on the touch button 

 

Appui BP 

Mode  

 < 3" 

> 3’’ 

>8’’ 

Activation 

 during 3’’ 

 

 

 

 during 3’’  

The Nano SPY 

remains 

activated 

Mesurement 

 1’’        = OK 
 1’’        = Technical alarm 

 3x1’’ = OK but paused 

 1’’        = In alarm state 

Off 

Off

 (If authorized by program) 

 

If the authorization of turning off the device is not programmed via MySirius then it will be not possible to turn 

off the Nano Spy. 

 

 

 

3’’ 

3’’ 

3’’ 

Summary of Contents for Nano SPY

Page 1: ...USER GUIDE Nano SPY Ref 11816J...

Page 2: ...CRIPTION 4 A CONTROL UNIT 4 B MOUNTING 4 IV OPERATION 5 A OFF STATE 5 B ACTIVATION 5 C TURNING OFF 5 D ACTIONS ON THE TOUCH BUTTON 5 V NANO SPY U CONNECTION 6 VI BATTERY REPLACEMENT 7 VII MAINTENANCE...

Page 3: ...not dispose of in a refuse dump or waste disposal bin Comply with existing legislation for disposal Power source this device is powered by a 3 6VDC type AA lithium battery ch V CE LABELING this device...

Page 4: ...Nano SPY LINK on the Ethernet network To ensure your safety during installation or an intervention on a device placed in a high position use proper equipment which is in good condition and provides ad...

Page 5: ...Sirius if it is contact with a Link It starts to measure and transmit its measurements to My Sirius at the frequency defined in MySirius then flashes regularly as a function of its status c Turning Of...

Page 6: ...be disconnected from the logger for replacement or for the exchange of the logger itself An IP67 Binder connector optional can be used to facilitate the connection of the sensors Connect only sensors...

Page 7: ...se discoloration or deformation of the surfaces VIII TECHNICAL FEATURES a Common features HMI 1 RGB LED 1 sensitive bouton Frequency band 2 4GHz from 2400 to 2483 5 MHz Maximum Radio Power 10 dBm Memo...

Page 8: ...ng range from 30 70 C Measurement range 50 105 C Accuracy standard version 0 3 C from 20 to 30 C 0 5 C outside this range Accuracy incubator version 0 2 C from 30 to 50 C 0 5 C outside this range IP r...

Page 9: ...20 C to 50 C 0 3 C from 80 C to 20 C and from 50 C to 140 C 0 5 C beyond these ranges Current input measurement range resolution accuracy control unit only No detection of probe failure for 0 20mA in...

Page 10: ...ance statement can be requested by email info group mms com IC CANADA This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 Thi...

Page 11: ...JRI 11 IX OPERATION CAPACITY...

Page 12: ...JRI 12...

Page 13: ...by offering you a fully integrated solution This global service offer includes both maintenance and a metrological service ensuring the optimum functioning of your devices or of your installation You...

Reviews: