2
-
4
JMA-9100/7100 Installation Manual > 2.INSTALLATION OF SCANNER UNIT > 2.1 EQUIPMENT CABLE
2.1.4
Cable end processing method
Allow for sufficient cable length so that maintenance, inspection, and repair work
can be easily executed. Ensure a place to store the cable.
1)
CFQ-6912
Cut off the metal shell connector.
Fig 2-4:
CFQ-6912 Cutting position
Remove about one meter of the outer skin, and then process the double braided
shield according to the procedures shown below.
Fig 2-5:
CFQ-6912 Processing of braided shield
abt.
80 mm
Terminal
Outer Shield
taping
1000 mm
Width for
clamping cable
30 mm
CFQ-6912
Outer Shield
abt.
abt.